Kikusui PLZ-4WH Series User Manual page 75

Table of Contents

Advertisement

Editing a Fast-Sequence Program
To configure a fast-sequence program, you first need to set the operation mode to CC mode
or CR mode. The program is executed the specified number of times.
Unlike with normal sequences, you cannot chain programs to be executed after the first
program. You can save one program (No. 11).
Press EDIT (SHIFT+A) to display a screen for configuring the sequence's program operation.
In the top screen, if you press
the bottom screen, if you press
In the screens for configuring the programs in the sequence, you can configure the following
items.
After you finish configuring the program settings, press NEXT (SHIFT+ ) to configure the
step settings.
Item
No.
Memo
Mode
Range
Loop
Last Load
Last Set
RPTSTEP
TIME BASE
1
PLZ-4WH
SEQ
No.
: 11
Memo : Pro
g
ram11
Mode : FCC
Ran
g
e : 8.25A ,650V
Loop : 0003
PREV
NEXT
Top
Setting
11
Up to 11 characters
FCC: CC mode
FCR: CR mode
8.25A,650V (example)
1 to 9998
9999: Infinite repetition
OFF: Load off
ON: Load on
0 to 100 % of the range
1
3 to 1024
0.1 ms to 100 ms
The minimum number of steps in a fast sequence is 3.
when the cursor is at Loop, the bottom screen appears. In
when the cursor is at Last Load, the top screen appears.
SEQ
Last Load : ON
Last Set
: 0.3000
A
RPTSTEP : 15
TIME BASE : 1ms
PREV
NEXT
Bottom
Description
Program number (1 to 10 are for the normal
sequences)
A memo
The program operation mode
The current and voltage ranges for the program vary
depending on the model.
The number of times that the program will repeat
The state of the load (on or off) after the sequence
finishes
The current at the end of the sequence
The last step number
Step execution time
4
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz164whPlz334whPlz1004whPlz4004whbPlz2004wb

Table of Contents