Kikusui PLZ-4WH Series User Manual page 11

Table of Contents

Advertisement

No.
Name
Rotary knob
10
11
CURSOR
INS key
DEL key
PREV key
NEXT key
LOCAL key
12
LOCK key
ENTER key
13
ABC key
SHIFT key
14
RECALL key
15
STORE key
C key
16
PAUSE key
B key
17
RUN/STOP key
A key
18
EDIT key
LEVEL key
19
% key
FREQ/DUTY key
20
Th/TL key
SW ON key
21
LOAD key
22
MODE key
23
+CV key
SET/VSET key
24
MENU key
RANGE key
25
V RANGE key
SLEW RATE key
26
SHORT key
OPP/OCP key
27
UVP key
Current Range
28
Voltage range
29
Lock icon
30
Remote icon
31
COARSE/FINE icon
32
mA/A
33
V
W
Operation status
34
Elapsed time
35
Setting
36
Short icon
37
Multi display
38
Set operation mode
39
PLZ-4WH
Used to make selections and change settings.
Up, down, left, and right keys.
Inserts a step (sequence editing).
Deletes a step (sequence editing).
Returns to the previous screen (menu settings).
Switches to the next screen (menu settings).
Used to switch to local mode from remote mode.
Used to set the key lock.
Used to confirm the input (menu settings).
Used to save settings to the preset memory.
Shift key.
Used to recall the setup memory.
Used to save the setup memory.
Used to access preset memory C.
Pauses the PLZ-4WH during sequence operation.
Used to access preset memory B.
Stops the PLZ-4WH during sequence operation.
Used to access preset memory A.
Used to edit sequences.
Used to set the switching level to a current or conductance value.
Used to set the switching level to a percentage.
Used to set the switching frequency and duty ratio.
Used to set the switching time.
Turns the switching function on and off.
Turns the load on and off.
Switches the operation mode.
Adds CV mode (constant voltage) to CC or CR mode.
Used to set the fundamental settings (current, conductance, voltage, or power).
Displays the menu setup screen.
Switches between the appropriate ranges (current, conductance, voltage, or power)
for the current operation mode.
Switches between voltage ranges.
Used to set the slew rate.
Turns the short function on and off.
Used to set the power at which overpower protection (OPP) is activated or the current
at which overcurrent protection (OCP) is activated.
Used to set the voltage at which undervoltage protection (UVP) is activated.
Displays the current range.
Displays the voltage range.
Appears when the key lock is enabled.
Appears during remote control.
Indicates whether the rotary knob is set to coarse or fine adjustment.
Displays the measured current value.
Displays the measured voltage value.
Displays the measured power value.
Indicates the operation mode being used or the status.
In CC+CV mode, CC or CV is displayed.
In CR+CV mode, CR or CV is displayed.
Displays the amount of time that has elapsed since the load was turned on.
Displays the fundamental setting (current, voltage, power, or conductance).
Appears when the short function is being used.
Displays settings other than the fundamental setting.
When a value can be set, it is underlined, and the item name is highlighted.
Displays the set operation mode.
Function
See
p. 30
p. 46
p. 45
p. 49
p. 30
p. 52
p. 51
p. 49
p. 81
p. 49
p. 81
p. 49
p. 61
p. 40
p. 41
p. 41
p. 31
p. 33
p. 35 , p. 37
p. 58
p. 42
p. 44
p. 54
p. 55
p. 45
p. 30
p. 33
p. 57
p. 44
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz164whPlz334whPlz1004whPlz4004whbPlz2004wb

Table of Contents