PLZ-4WH
Controlling Voltage Mode (CV mode and the +CV modes)
Connect the external voltage across pins 1 and 3 or pins 5 and 6 of the
EXT CONT connector.
If you are controlling the PLZ-4WH in the +CV modes, be sure to connect the external
voltage across pins 5 and 6.
Turn the POWER switch on, and make sure that the load is off.
Set the operation mode and the current range.
If you also want to control the current range externally, be sure to set the range to H.
If you have connected the external voltage across pins 1 and 3 of the
EXT CONT connector, from the menu, select "2.Configuration" >
"3.External" > "Control" > "V."
If you have connected the external voltage across pins 5 and 6 of the
EXT CONT connector, from the menu, select "2.Configuration" >
"3.External" > "Control CV" > "ON."
Doing so enables the external control of CV mode.
Setting Control to V and Control CV to ON from the menu enables the "Control CV"
that you have connected to pins 5 and 6 of the EXT CONT connector.
Turn the power switch off and then on again.
The menu settings are applied.