Increasing the magnification in the step setting monitor screen
You can increase the magnification that the steps are monitored at.
See
p. 77
Press
magnification. There are eight magnifications, from M1 to M8. The numbers indicate the
number of steps that are displayed on a single screen. M1 is the maximum magnification.
When you move the cursor to the step number by pressing
using the rotary knob, the waveform moves so that the selected step is in the center of the
rectangular monitor area.
When the magnification is set to M1, you can use the rotary knob to move one step at a time
and monitor the steps in detail. In the same way, when the magnification is M2, you can move
by two steps at a time; when the magnification is M3, you can move by three steps at a time;
and when the magnification is M8, you can move by eight steps at a time.
You can monitor all the steps up to the specified last step.
Press PREV (SHIFT+ ) to return to the previous screen.
FILL function
You can use the FILL function to automatically set the currents of a group of steps by setting
See
p. 77
the currents of the step on each end of the group.
In the monitor screen, press INS (SHIFT+
Item
DATA1
DATA2
START
STOP
1
Press
Memo
first step. In the same way, set DATA2 (the current of the last step), START (the step number
You can set the number of
of the first step), and STOP (the step number of the last step).
the last step to any value
After you have finished making the settings, press ENTER to return to the monitor screen.
up to 1024, but the last
step that can be
monitored is determined
In the example in the figure below, the same waveform is repeated twice.
by the value that you set
for RPTSTEP when you
edited the program.
PLZ-4WH
to move the cursor to the magnification, and use the rotary knob to change the
10.00
STEP:0014
A
FILL
DATA1 : 0.1620
A
DATA2 : 3.1620A
START : 0016
STOP : 1024
ENTER
M1
Setting
0 to 100 % of the range
0 to 100 % of the range
1 to 1024
1
1 to 1024
You can set the number of the last step to any value up to 1024, but the last step that can be monitored
is determined by the value that you set for RPTSTEP.
or
to move the cursor to DATA1, and use the rotary knob to set the current of the
First, set the first step to 16 and the current to 0.162 A, and set the last step to 100 and
the current to 1.164 A. Then, set the first step to 101 and the current to 0.164 A, and set
the last step to 200 and the current to 1.164 A.
Steps 16 to 100
Steps 101 to 200
10.00
STEP:0014
A
FILL
DATA1:
0.1620
DATA1:
A
DATA2:
3.1620
DATA2:
A
START: 0016
START: 0101
STOP :
0100
STOP :
ENTER
M1
M1
Editing Steps in a Fast Sequence
) to display the FILL screen.
Description
The current of the first step
The current of the last step
The step number of the first step
The step number of the last step
Current
3.162 A
(DATA2)
10.00
STEP:0014
A
FILL
0.1620
A
3.1620
A
0.162 A
(DATA1)
0200
ENTER
Step
(START) (STOP) (START) (STOP)
and then change the step
100 101
200
16
4
77