First Edition • First Printing
Starting the Engine
Diesel models
1
At the ground controls, turn the key switch to
the desired position.
2
Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
on position.
The engine glow plugs will automatically start
when the machine is turned on.
3
At the ground controls: The LCD
screen will display the glow plug
symbol when the automatic glow
plugs are on.
4
At the platform controls: The glow plug
indicator light will come on when the automatic
glow plugs are on.
5
When the glow plugs turn off, start the engine.
Move and hold the engine start toggle switch
or press and hold the engine start button.
6
If the engine fails to start or dies, the restart
delay will disable the start switch for
3 seconds.
Part No. 1306265GT
Operating Instructions
Emergency Stop
Push in the red Emergency Stop button to the off
position at the ground controls or the platform
controls to stop all machine functions and turn the
engine off.
Repair any function that operates when either red
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform red Emergency Stop button.
Auxiliary Power
Use auxiliary power if the primary power source
fails.
1
Turn the key switch to ground or platform
control.
2
Pull out the red Emergency Stop button to the
on position.
3
Press down the foot switch when using the
controls from the platform.
4
Simultaneously hold the auxiliary
power switch to either side and
activate the desired function.
Note: The drive function will not operate with
auxiliary power.