Inspections
At the Ground Controls
1
Select a test area that is firm, level and free of
hazards.
2
Turn the key switch to ground control.
3
Pull out the red Emergency Stop button to the
on position.
Result: The alarm should sound at the ground
controls.
4
Start the engine. See Operating Instructions
section.
Result: The beacons (if equipped) should
flash.
Test Emergency Stop
5
Push in the red Emergency Stop button to the
off position.
Result: The engine should shut off and no
functions should operate.
6
Pull out the red Emergency Stop button to the
on position and restart the engine.
38
Test Machine Functions
7
Do not push the function
enable button. Attempt to
activate each boom and
platform function button.
Result: No boom and platform functions
should operate.
8
Press and hold the function enable button and
activate each boom and platform function
button.
Result: All boom and platform functions should
operate through a full cycle. The descent
alarm should sound while the boom is
lowering.
Test the Tilt Sensor
9
Press the Maintenance button
above the LCD screen.
Navigate to the Real-time Data
screen.
Result: The LCD screen should display the
chassis angle and boom angle in degrees.