Vacuum mode + Cleaning brush + UV lamp (removing mites)
When the device is switched on in mode „B", pressing the mode button „1" switches it to the mode
Vacuum + UV lamp (removing mites).
By repeatedly pressing the „1" button, it is possible to switch successively between the 3 operating
modes of the vacuum cleaner.
WARNING
To prevent accidental injury, the UV lamp must be placed within 5 cm of the irradiated object and
the inclination of the device must not exceed 30 degrees. Outside this range, the UV lamp turns
off automatically.
When using the UV lamp mode, do not touch the hot air outlet with your hands.
You can switch off the device at any time during use by pressing the „2" button.

CLEANING AND MAINTENANCE

Failure to clean can damage the vacuum cleaner!
Before cleaning, disconnect the mains plug from the mains socket. Clean the body of the vacuum
cleaner with a damp cloth and then make sure that it is dry. Do not use solvents or abrasive cleaners.
Cleaning the dust tank
Turn off the machine, unplug it, press the dirt tank release button, remove the dust tank assembly,
and empty the contents. Loosen the top cover of the dirt tank, remove the filter and wash it with warm
water. Allow to dry properly before refitting. Also wash and clean the dust applied to the filter. After
cleaning, reattach to the device.
Cleaning the washable filter
The maximum suction effect will always be achieved with a clean filter and an empty dirt tank. Wash
the filter under running water, do not use hot water or detergents.
CAUTION: The bagless vacuum cleaner requires regular filter cleaning. If you do not clean the filters
properly, the passage of air may be blocked, which may lead to overheating and consequent
malfunction of the device, and may void your warranty. Filters must always be completely dry before
use. Do not use the device without the filter attached. We recommend cleaning the filters of the device
after each use. If the dust container is full, clean it immediately.
Cleaning the rotary brush
Loosen the screws of the rotating brush cover and remove it. Carefully cut with scissors to remove
any fibers or hair. After cleaning the brush, replace the cover and secure it with the screw.
UV lamp cleaning
To loosen it, unscrew the two screws and remove its cover. Gently clean the UV lamp with a dry soft
cloth. After cleaning, replace the UV lamp cover and secure it with two screws. Any dust or grease on
the UV lamp will immediately reduce its permeability and therefore the UV lamp must be cleaned
regularly. Do not touch the UV lamp with bare hands, as you will leave a mark on its surface, which
will impair the transmission of sterilizing light.
If you will not be using the appliance for a long time, please store it in a dry and cool place, do not
store the appliance in a humid environment or in direct sunlight.