TROUBLESHOOTING

If a problem occurs during the machine operation, alarms will be displayed on the screen of the machine.
OK
Input
to disable each alarm.
TROUBLES





DIAGNOSTICS

ELECTRIC
The machine does not switch on
SAMES KREMLIN
For any intervention on the machine :
- Flush the circuits,
- Shut off the compressed air,
- Depressurize the hoses by triggering the gun,
- Shut off the electric supply.
CAUSES
Trouble on the BASE fluid section
Trouble on the CATALYST fluid
section
Incorrect mixing ratio
Flow incorrectly adjusted
Irrelevant data capture between the
ratio
and
the
(Machine
unable
parameters requested)
FAULTS
Check the BASE circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Check the CATALYST circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Check the material levels in the supply
drums.
Check the starting of the pumps.
Check the CATALYST pressure towards
the BASE pressure.
Check that the P1 parameter (ratio) and
injection
volume
the P6 parameter (injection volume) are
to
give
the
compatible in injection capability terms
in
(refer to § 12).
Check that the isolating switch is on 'I'.
Check that the mains supply is connected.
No : connect it.
Check that the fuse on the electric card inside the
box is in working order.
No : change the fuse.
Check the electric wiring of the supply cable (bad
contact or other)
Page 36
SOLUTIONS
relation
to
the
ratio
CHECKINGS
Manual : 573.199.112