Parameters
Initialization mode (values of the high and low
thresholds of the movement sensors)

OK : to activate that mode
Flushing time

Minimum value : 10 seconds
Maximum value : 500 seconds
Flushing volume
Minimum value : 10 cc

Maximum value : 5000 cc
Number of thousands of cycles before
preventive maintenance on the A pump

Minimum value : 1
Maximum value : 9999
Number of thousands of cycles before
preventive maintenance on the B pump

Minimum value : 1
Maximum value : 9999
Percentage of dry extract in the base

Minimum value : 0 %
Maximum value : 100 %
Ratio Test mode

OK

VALIDATION OF THE INITIALIZATION MODE

That mode enables the machine to define the high and low settings of the movement sensor on each
pump.
After validating the
on the BASE pump piston : open the gun or the BASE drain valve to make the piston go down.
Once the BASE pump piston is in low position, close immediately the valve or the gun avoid the
decompression of the circuit, then input
Then, the piston displays
gun or the BASE drain valve to make the piston go up.
OK
Input
.
The machine displays
CATA drain valve to make the piston go down.
Once the CATA pump piston is in low point, close immediately the valve or the gun avoid the
decompression of the circuit, then input
Then, the piston displays
gun or the CATA drain valve to make the piston go up. When the piston is up, close immediately the
circuit to avoid the decompression.
OK
Input
.
After that last validation, the machine comes back to the parameter
Caution : that parameter must be modified only when changing the sensor
(disassembly or re-cabling) or when updating the software or or of the
electronic card or when changing a barrier Zener (CA and CB only). If the
procedure is launched, it must be carried out in entirety, if not : the machine
will not work correctly any more.
SAMES KREMLIN
Description
: to activate that mode

parameter, the machine displays
A2
, it goes up and is waiting for the high setting of the BASE pump. Open the
b1
, and controls the down stroke of the CATA pump piston : open the gun or the
b2
, it goes up and is waiting for the high setting of the CATA pump : open the
.
OK
OK
.
Page 24
Factory adjustment
120 s
500 cc
500 cyc
(i.e. 500 000 cycles)
500 cyc
(i.e. 500 000 cycles)
50 %
A1
, and controls the down stroke

menu.
Manual : 573.199.112
Your
adjustments

Advertisement

Table of Contents
loading