10. INDICATIONS OF OPERATION GIVEN BY THE MACHINE
INDICATIONS GIVEN BY THE LEDS
Description
Red LED
Orange LED
Green LED
Green + orange LED
LED switched off
MESSAGES GIVEN BY THE DISPLAY UNIT
The messages given by the display unit are for your information only but do not stop the machine.
Number of cycles' overrun indication
Messages
Cyc.A
Cyc.b
Cyc.Ab
Fluids' consumption alarm
Messages
--A--
--b--
SAMES KREMLIN
Function
Fault
Working
Production
Waiting
Programming
Overrun of the number of cycles configured at the P13 parameter
Overrun of the number of cycles configured at the P14 parameter
Overrun of the number of cycles configured at the P13 & P14 parameters
A fluid consumption alarm A container empty
(volume fixed by the P8 parameter)
OK (during at least 3 seconds) : reset of low level pump shut off –A-
This message is displayed in production. Press OK for 3 seconds : the message
disappears. The end of drum sensor resets to 0.
B fluid consumption alarm B container empty
(volume fixed by the P9 parameter)
OK (during at least 3 seconds) : reset of low level pump shut off –B-
This message is displayed in production. Press OK for 3 seconds : the message
disappears. The end of drum sensor resets to 0.
Page 33
Action
The machine stops
Function other than production (flushing, pot-
life alarm ...)
Indications
Indications
Manual : 573.199.112