TROUBLESHOOTING

For any intervention on the CYCLOMIX
- Flush the circuits,
- Shut off the compressed air,
- Depressurize the hoses by triggering the gun,
- Shut off the electric supply.
If a problem occurs during the operating of the CYCLOMIX
the screen of the CYCLOMIX
Enter
to acquit each alarm (we advice you to keep active the error 6 even if you can can desactivate
it).
TROUBLES
(Caution:
this
error
appears only in F1 mode
(production) and except
the
priming
/regeneration stage)
SAMES KREMLIN
TM
MICRO.
CAUSES
BASE flowmeter blocked.
CATA flowmeter blocked.
Incorrect mixing ratio
Flow improperly adjusted
Time between air opening and fluid
opening upper than 6 s
Flow switch blocked
Air leak
VP6 valve leaking
There is no signal from the flow-
switch whereas there are impulses on
the base flowmeter or on the catalyst
flowmeter.
Page 33
TM
MICRO :
TM
MICRO, some alarm will be displayed on
SOLUTIONS
Check the fluid circuit (pump, valve).
Clean or change.
Check or install a filter upstream the
flowmeter.
Check the fluid circuit (pump, valve).
Clean or change.
Check or install a filter upstream the
flowmeter.
Check the pressure differential : the
CATA pressure must be higher than the
BASE pressure of 15%
Trigger the gun quickler.
Change the flow switch.
Remove VP6 and check the correct
operating.
Change the valve if necessary.
Check the good operation of the flow-
switch. Change it if necessary.
Control the good operation of the
electronic card.
Increase the value of P12.
Manual : 573.191.112