CONNECTION OF THE CONTROL BOX AND OF THE FLUID FRAME

The PU 3000 must be connected to a
dry and clean compressed air network
(minimum 4 bar / 58 psi) and to a single
phase electric supply (115V / 230V)
connected to an isolating switch. The
electric supply must have an appropriate
protection (30 mA).The network ground
will be connected in the control box on a
connect provided and identified with the
symbol
.
Before connecting the PU 3000,
be certain the mains voltage is the
same as the one of the machine
(230 V).
If no, open the electric box removing the
protective housing and move the jumper
(230V  115V).
The machines with a stabilized electric
supply tolerate all voltage types (115V /
230V).
Connect the air equipment of the PU
3000 to the pneumatic network with a
conductive hose (minimum 16 mm / 5/8
dia).
Nota : these hoses are not supplied in
the standard version.
The air connection of the machine is
Female 3/4 BSP (air inlet valve).
The connection between the control box
and the electrovalves located on the
frame, is carried out via cable,
length : 8 m / 26.2".
Between the mixer outlet and the spray
gun, you must install a fluid hose, model
HP (high pressure) (
the pressures the pumps supply).
SAMES KREMLIN
act according to
Page 16
Fuse 160 mA
for machine with serial number < to 09Y1080
Fuse 315 mA
for machine with serial number >to 09Y1080
Machine with a stabilized electric supply