15. FEATURES - PU 3000 PNEUMATIC

COMPOSITION

BASE pump
CATALYST pump
Flushing pump

TECHNICAL FEATURES

Maximum air supply pressure
Maximum fluid outlet pressure of the PU 3000
Proportioning ratio / Fluid flow rate
Electrical supply of the supply unit
Air inlet connection
Fluid outlet connection (mixer)

SPECIFIC PARAMETERS

Parameters
Section of the A piston

Minimum value: 1 mm2
Maximum value : 99 999 mm2
Section of the B piston

Minimum value: 1 mm2
Maximum value : 99 999 mm2
SAMES KREMLIN
Motor :
Fluid section :
Motor :
Fluid section :
Option :
The control box of the PU 3000 mixing machine must be installed outside
the spray booth.
Description
1500 (only for PU 3000)
C100 (standard)
1500 (only for PU 3000)
F100 (Flowmax)
Flushing pump, model 02-C85
6 bar / 87 psi
0-6 bar / 0-87 psi or 6-40 bar / 87-580 psi
Refer to charts (§ 12 & 13)
115V / 230V - 10W
F 3/4 BSP (air inlet valve)
F 3/4 JIC
Factory adjustment
(for fluid section, model C100)
(for fluid section, model F100)
Page 42
Your adjustments
485
490
Manual : 573.199.112