SAMES KREMLIN PU 3000 Documentation page 49

Electronic mixing machine
Table of Contents

Advertisement

MATERIAL
No fluid flows when passing into production or
flushing mode.
The machine displays the correct mixing but the
consumption of catalyst is too important.
The machine displays the correct mixing but the
consumption of catalyst is not enough.
When the main menu page is displayed, fluid flows
out when the gun is open.
SAMES KREMLIN
FAULTS
Check if the valves are open :
No : - Check air supply (minimum 4 bar / 58 psi),
- Check the connection of the 25 pts cable,
- Check the correct operating of the
electrovalves.
Yes : - Check the fluid pressure,
- Check the static mixer.
Check the grounds of the machine (230V intake
and ground cable of the fluid module)
Check the grounds of the machine.
Check the valves
Checking of the valve : look at what is flowing
-if it is solvent, change the valve (VP1)
-if it is base, change the valve (VP2A)
-if it is catalyst, change the valve (VP2B)
Page 37
CHECKINGS
Manual : 573.199.112

Advertisement

Table of Contents
loading

Table of Contents