DLP-5 Connecting to the Unit Using Telnet
Introduction
The Total Access 6XX comes pre-programmed for default Telnet access. The following IP
parameters apply:
For security purposes, change the default Telnet password during the initial unit
configuration. (Refer to System Config > Management > Telnet Access > User List on
page 53 for more details.)
If the Total Access 6XX is part of a management cluster connected to the local network, you may use a PC
connected to the network to Telnet into the unit. This procedure details the steps which must be performed
to Telnet into the unit.
Prerequisite Procedures
Complete DLP-3, Setting IP Parameters and DLP-4, Verifying Communications Over an IP LAN.
Tools and Materials Required
Access to a PC or other computer connected to the LAN.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic equipment can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electronic
components. Place equipment in antistatic packing material when transporting or storing.
When working on equipment, always place it on an approved antistatic mat that is
electrically grounded.
61200624L1-1B
IP Address: 10.0.0.1
Subnet Mask: 255.255.255.0
User: guest
Password: password
© 2004 ADTRAN, Inc.