ADTRAN 604 System Manual page 85

Total access 600 series
Hide thumbs Also See for 604:
Table of Contents

Advertisement

Total Access 600 Series System Manual
I
(FXS) > C
NTERFACES
Indicates the port of the FXS module.
I
(FXS) > C
NTERFACES
Choices are given below. Default is
This mode must match the network configuration and/or how each port is being used. Each
port on the FXS Module is independent and should be set accordingly.
L
S
OOP
TART
G
S
ROUND
TART
TR08 S
INGLE
TR08 UVG
DPO
T
(E&M)
ANDEM
I
(FXS) > C
NTERFACES
Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal
that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this
number should be increased. A higher number indicates more attenuation which equals lower volume. The
value entered must be less than 10 dB. Default is
I
(FXS) > C
NTERFACES
Sets the RX direction level points. This signal will change the volume of the voice. A higher number
indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default
is
. The maximum signal is
3.0 dB
61200624L1-1B
> P
ONFIG
ORT
> M
ONFIG
ODE
L
S
.
OOP
TART
Sets the port to use FXS loop start signaling on the T-span and loop start
supervision on the analog 2-wire interface.
Sets the port to use FXS ground start signaling on the T-span and ground
start supervision on the analog 2-wire interface.
Sets the port to use Single Party Channel Unit signaling on the T-span
(as defined by TR-TSY-000008) and loop start supervision on the
analog 2-wire interface.Only available when using a T1 network
interface.
Sets the port to use Universal Voice Grade signaling on the T-span (as
defined by TR-TSY-000008) and either loop start or ground start
supervision on the analog 2-wire interface. Only available when using a
T1 network interface.
Sets the port to use Dial Pulse signaling to originate dialed numbers.
Only available when using a T1 network interface.
Sets the port to use E&M signaling on the T-span and either loop start or
ground start supervision on the analog 2-wire interface. See the
submenus for more information. Only available when using a T1
network interface.
> T
(
B)
d
ONFIG
X
6.0 dB
> R
(
B)
d
ONFIG
X
.
0.0 dB
© 2004 ADTRAN, Inc.
Section 4 User Interface Guide
.
T
ANDEM
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents