Dalsa Everywhereyoulook Linea Lite GigE User Manual page 92

Table of Contents

Advertisement

PTP Port Last Event
None
Power up
Initialize
Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout
Expires
Announce Receipt
Timeout Expires
Synchronization Fault
Master Clock Selected
Recommended State
Master
Recommended State
Grand Master
Recommended State
Slave
Recommended State
Passive
PTP Transport Protocol
PTP Servo Step Threshold
(in us)
Threshold_10
Threshold_20
Threshold_100
Threshold_500
Threshold_1000
Threshold_2000
Timestamp Modulo Event
Timestamp Modulo Event
Frequency
Timestamp Modulo Start
Time
Timestamp Modulo Actual
Start Time
Gev Timestamp Latch
Gev Timestamp Value
Gev Timestamp Tick
Frequency
Gev Timestamp Reset
90 • Operational Reference
ptpPortLastEvent
None
Powerup
Initialize
DesignatedEnabled
DesignatedDisabled
FaultCleared
FaultDetected
StateDecisionEvent
QualificationTimeoutExpires
AnnounceReceiptTimeoutExpires
SynchronizationFault
MasterClockSelected
RS_Master
RS_GrandMaster
RS_Slave
RS_Passive
ptpTransportProtocol
ptpServoStepThreshold
Threshold_10
Threshold_20
Threshold_100
Threshold_500
Threshold_1000
Threshold_2000
timestampModulo
timestampModuloFrequency
timestampModuloStartTime
timestampModuloActualStartTime
GevtimestampControlLatch
GevtimestampValue
GevtimestampTickFrequency
GevtimestampControlReset
Logs the last PTP changed state event defining the last
current status.
None
Power up
Initialize
Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout Expires
Announce Receipt Timeout Expires
Synchronization Fault
Master Clock Selected
Recommended State Master
Recommended State Grand Master
Recommended State Slave
Recommended State Passive
Describes the PTP Transport Protocol used.
Specifies the servo step threshold (in μs). When the clock
offset with the master exceeds the threshold, the servo
unlocks and offset adjustment is started.
10 μs threshold.
20 μs threshold.
100 μs threshold.
500 μs threshold.
1000 μs threshold.
2000 μs threshold.
Specifies the additional interval between the current
timestamp tick and the event generated. This interval has
an 80ns accuracy. Note that the value zero disables the
event generator.
Returns the frequency of the timestamp Modulo Event (in
Hz).
Specifies the timestamp value that must be exceeded by
the incrementing timestamp counter before the modulo
event starts. This Feature is also used for a "Future" Frame
Acquisition.
Displays the actual modulo event start time as used by the
device. When the user specified
"timestampModuloStartTime" is in the future,
timestampModuloActualStartTime=
timestampModuloStartTime. When the user specified
"timestampModuloStartTime" has already past, the camera
automatically recalculates a future value for
"timestampModuloStartTime" using the user set
"timestampModulo" feature value. This new start time is
reported by "timestampModuloActualStartTime".
Latch the current timestamp internal counter value in the
timestampValue feature. (WO)
Returns the 64-bit value of the timestamp counter. (RO)
Indicates the number of timestamp ticks (or increments)
during 1 second (frequency in Hz). (RO)
Resets the timestamp counter to 0. (WO)
Linea Lite GigE Series Camera
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Invisible
Invisible
Invisible
Invisible

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea lite gige