Dalsa Everywhereyoulook Linea Lite GigE User Manual page 65

Table of Contents

Advertisement

Rotary Encoder Output
Mode
Position
Motion
Rotary Encoder Direction
Clockwise
Counter Clockwise
Rotary Encoder Input A
Source
Line 1
Line 3
Rotary Encoder Input B
Source
GND
Line 2
Rotary Encoder Source
Activation
Rising Edge
Any Edge
Rotary Encoder Rescaler
Order
Multiplier Divider
Divider Multiplier
Rotary Encoder Multiplier
Rotary Encoder Divider
Line Selector
Line 1
Line 2
Line 3
Line 4
Line 5
Linea Lite GigE Series Camera
rotaryEncoderOutputMode
Position
Motion
rotaryEncoderDirection
Clockwise
CounterClockwise
rotaryEncoderInputASource
Line1
Line3
rotaryEncoderInputBSource
GND
Line2
rotaryEncoderSrcActivation
RisingEdge
AnyEdge
rotaryEncoderRescalerOrder
multiplierDivider
dividerMultiplier
rotaryEncoderMultiplier
rotaryEncoderDivider
LineSelector
Line1
Line2
Line3
Line4
Line5
Specifies the conditions for the Rotary Encoder interface to
generate a valid Encoder output signal.
On the camera, the "position" behaviour exists, but the
number of counts is small (7-bits / 128 counts). The
encoder can reverse for 256 ticks and then go forward and
behave as expected for "position" style behaviour. If the
user exceeds 256 ticks, the count will max out, but will not
reset. When the user starts going forward again, 256 lines
will be dropped / ignored and then resume output.
The triggers are generated for all motion increments in
either direction.
Specifies the phase which defines the encoder forward
direction.
Inspection goes forward when the rotary encoder direction
is clockwise (phase B is ahead of phase A).
Inspection goes forward when the rotary encoder direction
is counter clockwise (phase A is ahead of phase B).
Selects which input line to assign to the rotary encoder
input A (also known as shaft encoder). Note that the Line
Mode feature must be set to Input. The list of supported
input line sources is device-specific.
Line1 is assigned to the Rotary Encoder Input A.
Line3 is assigned to the Rotary Encoder Input A.
Selects which input line to assign to the rotary encoder
input B (also known as shaft encoder). Note that the Line
Mode feature must be set to Input. The list of supported
input line sources is device-specific.
Rotary Encoder Input B is not used
Line2 is assigned to the Rotary Encoder Input B
Specifies the signal edge(s) use to increment the rotary
encoder.
The rotary encoder uses the rising edge of the source
signal.
The rotary encoder uses either the rising edge or falling
edge of the source signal.
Specifies the order that the multiplier and divider are
applied.
The signal is multiplied before been divided.
The signal is divided before been multiplied.
Specifies a multiplication factor for the rotary encoder
output pulse generator.
Specifies a division factor for the rotary encoder output
pulse generator.
Selects the physical line (or pin) of the external device
connector to configure.
Index of the physical line and associated I/O control block
to use. Pin 1 and Pin 2 is the RS-422 Input Port 1+, 1-,
respectively.
Index of the physical line and associated I/O control block
to use. Pin 3 and Pin 4 is the RS-422 Input Port 2+ and 2-
, respectively.
Index of the physical line and associated I/O control block
to use. Pin 6 and Pin 7 is the Port 3+ and 3-, respectively.
Index of the physical line and associated I/O control block
to use. Pin 11 and Pin 12 is Output Port 4+ and 4-,
respectively.
Index of the physical line and associated I/O control block
to use. Pin 13 and Pin 14 is the Output 5+ and 5-,
respectively.
Operational Reference • 63
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Guru
DFNC
DFNC
Beginner
DFNC
Beginner
Beginner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea lite gige

Table of Contents