Counter Reset Source
Reset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Trigger
Valid Frame Trigger
Rejected Frame Trigger
MultiFrame End Trigger
Line 1
Line 2
Timer 1 End
Counter 1 End
Counter Reset Input Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Duration
Counter Value
Counter Value At Reset
Counter Reset
Timer Selector
Timer 1
Timer 2
Timer Mode
Off
Active
Timer Status
Timer Idle
Timer Trigger Wait
Timer Delaying
Timer Active
Timer Completed
68 • Operational Reference
counterResetSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
InvalidFrameTrigger
FrameBurstEnd
Line1
Line2
Timer1End
Counter1End
counterResetLineActivation
RisingEdge
FallingEdge
AnyEdge
counterDuration
counterValue
counterValueAtReset
counterReset
timerSelector
Timer1
Timer2
timerMode
Active
timerStatus
TimerIdle
TimerTriggerWait
TimerDelaying
TimerActive
TimerCompleted
Selects the signal source to reset the counter then waits
for the next countStartSource signal or event.
Off
Reset on reception of the Reset Icommand.
Reset on reception of the Acquisition Start.
Reset on reception of the Acquisition End.
Reset on reception of the Exposure Start event.
Reset on reception of the Exposure End event.
Reset the counter on the reception of the Readout Start
event.
Reset the counter on the reception of the Readout End
event.
Reset on reception of the Frame Trigger event.
Reset on reception of the Valid Frame Trigger event.
Reset on reception of the Invalid Trigger event.
Reset on reception of the Frame Burst end event.
Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Reset counter on the specified transition on line 2.
Reset on reception of the Timer 1 End.
Reset on the reception of the Counter 1 end.
Specify the edge transition on the selected line that will
reset the selected counter.
Reset counter on rising edge of the selected signal.
Reset counter on falling edge of the selected signal.
Reset counter on the falling or rising edge of the selected
signal.
Sets the duration (or number of events) before the
CounterEnd event is generated.
Read the current value of the selected counter. (RO)
Reads the value of the selected counter when it was reset
by a trigger or by an explicit Counter Reset command.
(RO)
Resets the selected counter to zero. The counter starts
immediately after the reset. To temporarily disable the
counter, set the Counter Event Source feature to Off.
(WO)
Selects which timer to configure.
Configure Timer 1.
Configure Timer 2.
Select the timer mode. The selected Timer is Active or
Disabled. When Disabled, the Timer can be configured.
Off
The selected Timer is Disabled.
The selected Timer is Enabled.
Returns the current state of the timer. (RO)
The timer is idle. The CounterStartSource feature is
set to off.
The timer is waiting for a start trigger.
The timer is counting the requested delay.
The timer is counting for the specified duration.
The timer reached the TimerDuration count.
Linea Lite GigE Series Camera
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea lite gige

Table of Contents