Dalsa Everywhereyoulook Linea Lite GigE User Manual page 66

Table of Contents

Advertisement

Line Format
RS422
Single Ended
Line Mode
Input
Output
Line Status
Line Inverter
Input Line Detection Level
Threshold for TTL
Input Line Debouncing
μs)
Period (in
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Line
Pulse on: Start of Exposure
Pulse on: Rejected Trigger
Pulse on: End of Exposure
Pulse on: Valid Line Trigger
Pulse on: Invalid Line
Trigger
Pulse on: End of Timer 1
Pulse on: End of Counter 1
Pulse on: Input 1 Signal
Pulse on: Input 2 Signal
Output Line Pulse Signal
Activation
Rising Edge
Falling Edge
Any Edge
64 • Operational Reference
LineFormat
RS422
SingleEnded
LineMode
Input
Output
LineStatus
False / True
LineInverter
False / True
lineDetectionLevel
Threshold_for_TTL
lineDebouncingPeriod
outputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnInvalidTrigger
PulseOnEndofExposure
PulseOnValidLineTrigger
PulseOnInvalidLineTrigger
PulseOnTimer1End
PulseOnCounter1End
PulseOnInput1
PulseOnInput2
outputLinePulseActivation
RisingEdge
FallingEdge
AnyEdge
Specify the current electrical format of the selected
physical input or output. Applies to all physical lines. (RO)
The line accepts or sends RS422 level signals.
The line is single ended input for 3.3V/5V/12V/24V or
output for 3.3V LVTTL
Reports if the physical Line is an Input or Output signal.
(RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
The line is an input line.
The line is an output line.
Returns the current status of the selected input or output
line. (RO)
Controls whether to invert the polarity of the selected
input or output line signal.
Specifies the voltage threshold required to recognize a
signal transition on an input line.
A signal below 0.8V will be detected as a Logical LOW and
a signal greater than 2.4V will be detected as a Logical
HIGH on the selected input line.
Specifies the minimum delay before an input line voltage
transition is recognizing as a signal transition.
Selects which internal signal or event driven pulse or
software control state to output on the selected line. Note,
the LineMode feature must be set to Output. The List of
supported output line sources is product-specific. The
Event Control section
provides details and timing diagrams
for the supported trigger modes.
Off
Line output is Open
The
outputLineValue
feature changes the state of the
output
Generate a pulse on the start of the Frame Active event
Generate a pulse on the start of the Line Active
Generate a pulse on the ExposureStart event. This option
is typically used to trigger a strobe light.
Generate a pulse on the Invalid Trigger event.
Generate a pulse on the ExposureEnd event. This option is
typically used to trigger a strobe light.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid LineTrigger event.
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
Specifies the input line activation mode to trigger the
OutputLine pulse.
Specifies that the trigger is considered valid on the rising
edge of the source signal.
Specifies that the trigger is considered valid on the falling
edge of the source signal.
Specifies that the trigger is considered valid on the falling
or rising edge of the source signal.
Linea Lite GigE Series Camera
Expert
Expert
Expert
Beginner
Expert
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea lite gige

Table of Contents