Dalsa Everywhereyoulook Linea Lite GigE User Manual page 69

Table of Contents

Advertisement

Counter Start Source
Off
Acquisition Start
Exposure Start
Exposure End
Rejected Trigger
Frame Start
Line 1
Line 2
Timer 1 End
Counter 1 End
Counter Start Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Incremental
Source
Off
Acquisition Start
Exposure Start
Exposure End
Frame Start
Rejected Trigger
Line 1
Line 2
Internal Clock
Timer 1 End
Counter Incremental Line
Activation
Rising Edge
Falling Edge
Any Edge
Linea Lite GigE Series Camera
counterStartSource
AcquisitionStart
ExposureStart
ExposureEnd
InvalidTrigger
FrameStart
Line1
Line2
Timer1End
Counter1End
counterStartLineActivation
RisingEdge
FallingEdge
AnyEdge
counterIncrementalSource
AcquisitionStart
ExposureStart
ExposureEnd
FrameStart
InvalidTrigger
Line1
Line2
InternalClock
Timer1End
counterIncrementalLineActivation
RisingEdge
FallingEdge
AnyEdge
Select the counter start source. Counter increments from
0 to the value of the counterDuration feature.
Off
Counter is stopped.
Counter starts on the reception of the Acquisition Start
event.
Counter starts on the reception of the Exposure Start
event.
Counter starts on the reception of the Exposure End
event.
Counter starts on the reception of an Invalid Trigger
event.
Counter starts on the reception of the Frame Start event.
Counter starts on the specified transitions on Line 1.
See Input Signals Electrical Specifications.
Counter starts on the specified transitions on Line 2.
Counter starts on the reception of the Timer 1 End event.
Counter starts on the reception of the Counter 1 End
event.
Selects the activation mode of the input line trigger which
starts the counter. This is only applicable when the
counterStartSource feature selects a physical Line.
Starts counting on rising edge of the selected Line.
Starts counting on falling edge of the selected Line.
Starts counting on the falling or rising edge of the
selected Line.
Select the event source which increments the counter.
The
Event Control section
diagrams for the supported events.
Off
Counter is stopped.
Counts the number of Acquisition Start events.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Frame Start events.
Counts the number of Invalid Trigger events.
Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting).
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting).
The counter increments on each microsecond tick of the
device internal Clock.
Counts the number of Timer 1 End events.
Selects the counter signal activation mode for line inputs.
The counter increments on the specified signal edge or
level.
Increment the counter on the rising edge of the selected
I/O Line.
Increment the counter on the falling edge of the selected
I/O Line.
Increment the counter on the falling or rising edge of the
selected I/O Line.
provides details and timing
Operational Reference • 67
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC