Piv Trigger Minimum Interval - JAI AD-131GE User Manual

Digital 2ccd progressive scan hdr / high frame rate camera
Table of Contents

Advertisement

10.6.7.6

PIV trigger minimum interval

SYNC
Minimum Trigger Interval(Line)
Mode
SYNC
LVAL
Mode=
ASYNC
SYNC
(Reference)
In PIV Mode 1,2,3 and if [JAI Partial Scan]=False is set, the minimum Trigger interval is as
follows:(Frame interval [L] in continuous mode = 982 Line)
[PIV Mode 1 Minimum Trigger interval] ≧ 1968 Line
[PIV Mode 2 Minimum Trigger interval] ≧ 1969 Line
[PIV Mode 3 Minimum Trigger interval] ≧ 1969 Line
[PIV Mode 4:PIV Exposure & PIV Interval values are set at maximum; minimum Trigger
interval] ≧ 1989 Line
[PIV Mode 4:PIV Exposure & PIV Interval values are set at minimum, minimum Trigger
interval] ≧ 1968 Line
AD-131GE
V-Binning
{(([PIV Exposure Time]x8)+[PIV Interval]+294) /
Off
[1LineH.clock:1660]}+(Frame interval in continuous
mode[L]×2) + 4 L
"round off after the decimal point"
V-Binning
{(([PIV Exposure Time]x8)+[PIV Interval]+596) /
On
[1LineH.clock:1660]}+(Frame interval in continuous
mode[L]:494×2) + 4 L
"round off after the decimal point"
at Binning Vertical=1 1L=32.344μs
at Binning Vertical=2 1L=38.189μs
66