Minimum Interval Of The Trigger Input On Each Operation Mode - JAI CM-030PMCL-RH User Manual

1/3” progressive scan monochrome remote head camera
Table of Contents

Advertisement

6.3.5.

Minimum interval of the trigger input on each operation mode

Mode
Continuous
Pre-select
Pulse width
EPS(Smear less)
*1) The minimum interval for trigger modes shows in case of LVAL sync mode. For LVAL sync
mode, the accumulation time should be added.
*2) In order to maintain the minimum interval on the partial scan, it is necessary so that the
exposure time should not exceed the lines for the continuous mode. When the exposure is
set at longer than that of the continuous mode, the interval becomes longer than the
described by figures (Exposure time – Lines of the continuous).
CM-030PMCL-RH
Read out mode
Full
2/3 Partial
1/2 Partial
1/4 Partial
1/8 Partial
V. Binning
Full
2/3 Partial
1/2 Partial
1/4 Partial
1/8 Partial
V. Binning
Full
2/3 Partial
1/2 Partial
1/4 Partial
1/8 Partial
V. Binning
Full
2/3 Partial
1/2 Partial
1/4 Partial
1/8 Partial
V. Binning
22
Line(Trigger minimum
interval)*
511
356
284
176
122
257
513
359
287
179
125
259
513
359
287
179
125
259
578
423
351
243
189
324

Advertisement