Trigger Operation Controlled By Pulse Width (Pwc) - JAI AD-131GE User Manual

Digital 2ccd progressive scan hdr / high frame rate camera
Table of Contents

Advertisement

10.6.4

Trigger operation controlled by pulse width (PWC)

In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to
have a long time exposure. The maximum recommended time is <60 frames.
If the sync mode is set at ―Sync‖, the exposure time is the same for both Camera #0 and #1 as
the trigger to Camera #0 is applied to Camera #1.
In PWC mode, only LVAL asynchronous accumulation is effective.
For details of the timing, please refer to chapter 8.4 and fig. 44 and 45.
To use this mode:
Set function:
Input:
This function can be set by selecting Pulse-width control in Exposure mode of JAI Acquisition Control.
However, Acquisition Mode, Sync Mode, Exposure Time, and so on should be set.
Important Note:
The minimum duration of the trigger is 2L. The minimum period of trigger is as follows.
SYNC Mode
Smearless
Enable
SYNC Mode
False
=SYNC
True
SYNC Mode
False
=ASYNC
True
Pulse-width trigger is available only in LVAL Async accumulation.
AD-131GE
Acqusition mode
Trigger mode
Sync mode
Exposure Mode
Exposure time
Other functions
External Trigger
Minimum Trigger interval (Line)
LVAL
(Trigger Pulse width: Min.2L) + Frame interval in
ASYNC
continuous operation(L) + 4L
LVAL
(Trigger Pulse width:Min.197L+2L) + Frame interval in
ASYNC
continuous operation(L) + 4L
LVAL
(Trigger Pulse width: Min.2L) + Frame interval in
ASYNC
continuous operation (L) + 4L
LVAL
(Trigger Pulse width : Min.197L+2L) + Frame interval
ASYNC
in continuous operation(L) + 4L
:Frame Start
:ON
:Refer to 10.5.4
:Trigger Width
:Exposure time/Exposure time(us)/
Exposure time(Raw)
Trigger Source
58