Timing Chart - JAI AD-131GE User Manual

Digital 2ccd progressive scan hdr / high frame rate camera
Table of Contents

Advertisement

10.6.3.1

Timing chart

Following charts are examples if Sync mode is set to Sync and in full frame operation.
If Sync mode is set to Sync, the timing of trigger input is the same for both camera #0 and #1.
The exposure time can be set individually but the output timing of the video output is the
same.
Note: 2.8L to 3.8L after the exposure end of the longest exposure.
T1
V-Binning OFF
0.2L(6.03μs)
V-Binning ON
0.3L(11.86μs)
Ext. Trigger
FVAL
LVAL
EEN
Exposure
DATA out
V-Binning Off
V-Binning On
AD-131GE
1 LVAL = 1660 clock (32.344μs)
T2
2.8L ~ 3.8L
1.8L ~ 2.8L
Fig.41 Edge Pre-select LVAL asynchronous
Exposure Period
t1
t1(Exposure start delay)
0.2L (6.03μs)
0.3L (11.587μs)
Fig.42 Edge Pre-select LVAL asynchronous details
T3
977L
489L
t2
t3
t2
2.8L ~ 3.8L
1.8L ~ 2.8L
56
T4
966L
483L
t3(Data output delay)
10.8L ~ 11.8L
5.8L ~ 6.8L