If Software trigger 0 is selected as the trigger source for Frame Start Trigger of Camera 0 and
Camera 1, the command for Camera 0 and command for Camera 1 are mixed. Therefore, Software
trigger 0 command for Camera 0 and Camera 1 are applied to both Camera 0 and Camera 1, and the
function does not operate properly.
Fig. 21
2) Action Command
In the action command of AD-131GE, Software 2 and 3 are used as action commands
and sent to the selected source.
If the source is set to Action 1, for instance, it is changed to Software trigger 2 in
the camera control tool.
Action 1 => Use Software Trigger 2
Action 2 => Use Software Trigger 3
3) ―Trigger Source = Software‖ in Frame Start and Transfer Start
For Frame Start and Transfer Start in the AD-131GE, ―Trigger Source = Software‖
can be set and Software command 0 and software command 1 can be sent.
Frame Start / Trigger Software command => Use Software Trigger 0
Transfer Start / Trigger Software command => Use Software Trigger 1
AD-131GE
Software Trigger setting restriction