10.2.3 Pulse Width trigger mode (PWC)

In this mode the accumulation time is equal the trigger pulse width. Here it is possible to have
long time exposure. The maximum recommended time is <2 seconds.
The accumulation can be LVAL synchronous or LVAL asynchronous.
The resulting video signal will start to be read out after the trigger rising edge.
For timing details, refer to fig. 19. through fig. 24 and fig.30 and 31.
To use this mode:
Important notes on using this mode
Trigger pulse width >2 LVAL to <2 seconds
The following table shows minimum trigger interval in synchronous accumulation mode
Full scan
2/3 Partial
1/2 Partial
1/4 Partial
1/8 Partial
V Binning
1) In case of a-synchronous mode, the exposure time should be added to the above table.
1254 L
894 L
716 L
452 L
322 L
630 L