Carry Out Test Run; Start The Welding Process - Fronius FDV 15 MF Operating Instructions Manual

Carriage
Table of Contents

Advertisement

Carry out
Perform a test run to check that all system components work together correctly. This is
test run
done without an arc and thus allows you to check all movements during the process:
Start the welding

Start the welding process:

process
1. Set the "Start LEFT / STOP / Start RIGHT" toggle switch to the de-
sired direction - The test run starts. To stop the process early, turn the
switch to the "STOP" (0) position.
IMPORTANT! Never leave the machine unattended, particularly when
it is moving automatically.
2. Carry out a visual check during the test run
3. Make any necessary corrections (welding torch position, direction of
travel, traversing speed, etc.)
1. Set the "Start LEFT / STOP / Start RIGHT" toggle switch to the desired
direction - the welding process starts. To stop the process early, turn
the switch to the "STOP" (0) position.
IMPORTANT! Never leave the machine unattended, particularly when
it is moving automatically.
2. Press the torch trigger to start the welding process
26