11. Bleed the hydraulic system of excess air,
according to "Bleeding the drive system".
12. Run the rider and make sure that there
are no oil leaks from the new shaft seals.
13. Check the oil level after test running and
top up as needed.
Replacing the Hydrostatic Transmission
Cable
Removing the Hydrostatic Transmission Cable
1.
Remove the frame plate by loosening the
screws.
2.
Loosen the hydrostatic transmission
cable's forward lock nut a 1/4 turn and
remove the locking spring.
3.
Remove the hydrostatic transmission
cable's forward clamp, which is attached
inside the centre bracket.
REPAIR INSTRUCTIONS
Frame plate
Front locking nut and locking spring
8042-039
6019-010
8009-203
77