Table E.2 Recommended Fuse and Circuit Breaker Ratings per NEC (480 Vac Input)
Model
Hp
CIMR-E7U
40P4
0.5/0.75
40P7
1
41P5
1.5/2
42P2
3
43P7
5
44P0
-
45P5
7.5
47P5
10
4011
15
4011
20
4015
25
4018
30
4022
-
4030
40
4030
50
*1 Input and Output Amps are based on the Normal Duty (ND) current rating. Consult the Specification section for details on the Heavy Duty (HD) and Normal Duty (ND) ratings.

Branch Circuit Overload Protection

All models have built-in UL evaluated motor overload protection. Motor overload protection is also provided in
accordance with the NEC and CEC. Additional branch circuit overload protection is not required for single motor
applications.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Input
Output
Amps
Amps
*1
*1
(Continuous
(Continuous
Rating)
Rating)
2.2
1.8
2.5
2.1
4.4
3.7
6.4
5.3
9
7.6
10.4
8.7
15
12.5
20
17
33
27
33
27
40
34
48
40
55
50.4
74
67.2
74
67.2
Peripheral Devices E - 3
Fuse
Selection Criteria
Maximum
Maximum
Time-Delay
Non-Time-Delay
Fuse Rating (A)
Fuse Rating (A)
4
10
4
10
8
12
10
15
15
20
15
30
25
30
30
30
45
50
45
50
60
70
70
80
80
70
100
100
100
100
Circuit Breaker
Selection Criteria
Maximum CB
Rating (A)
15
15
15
15
20
20
30
40
60
60
80
90
100
125
125

Advertisement