YASKAWA E7N Technical Manual page 260

Drive/bypass
Table of Contents

Advertisement

Monitor Data
The following table shows the monitor data. Monitor data can only be read.
Register No.
Drive status
0020H
Bits 8 to F
Fault details
0021H
Data link status
0022H
Bits 5 to F
0023H
Frequency reference
0024H
Output frequency
0025H
Output voltage reference U1-06
0026H
Output current
0027H
Output power
0028H
Torque reference
0029H
Not used
002AH
Not used
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table D.5 Monitor Data
Bit 0
Operation 1: Operating 0: Stopped
Bit 1
Reverse operation 1: Reverse operation 0: Forward operation
Bit 2
Drive startup complete 1: Completed 0: Not completed
Bit 3
Fault 1: Fault
Bit 4
Data setting error 1: Error
Bit 5
Multi-function digital output 1 (terminal M1 - M2) 1: ON 0: OFF
Bit 6
Multi-function digital output 2 (terminal M3 - M4) 1: ON 0: OFF
Bit 7
Not used
Not used
Bit 0
Overcurrent (OC) Ground fault (GF)
Bit 1
Main circuit overvoltage (OV)
Bit 2
Drive overload (OL2)
Bit 3
Drive overheat (OH1, OH2)
Bit 4
Not used
Bit 5
Fuse blown (PUF)
Bit 6
PI feedback reference lost (FbL)
Bit 7
External error (EF, EFO)
Bit 8
Hardware error (CPF)
Bit 9
Motor overload (OL1) or overtorque 1 (OL3) detected
Bit A
PG broken wire detected (PGO), Overspeed (OS), Speed deviation (DEV)
Bit B
Main circuit undervoltage (UV) detected
Main circuit undervoltage (UV1), control power supply error (UV2), inrush prevention
Bit C
circuit error (UV3), power loss
Bit D
Missing output phase (LF)
Bit E
Modbus communications error (CE)
Bit F
Operator disconnected (OPR)
Bit 0
Writing data
Bit 1
Not used
Bit 2
Not used
Bit 3
Upper and lower limit errors
Bit 4
Data integrity error
Not used
U1-01
U1-02
U1-03
U1-08
U1-09
Communications D - 11