22 • FlipTop Data Center: QM-FTDC
NOTE: The maximum continuous current from equipment under any external
load conditions shall not exceed a current limit that is suitable for the minimum
wire gauge used in interconnecting cables. The ratings on the connecting unit's
supply input should be considered to prevent overloading the wiring.
Attach the optional labels (included) to the passthrough telecommunication
connectors 1, 2 and 3.
1
2
3

Ground Wire Connections

Proper grounding is required. Connect the ground from the QM transmitter
(QM-FTDC) to earth ground. Connect the Cresnet shield at the
QM-RMCRX-BA to the chassis ground provided on the QM-RMCRX-BA. The
QM-RMCRX-BA chassis must also be connected to an earth ground (building
steel). Refer to the following grounding diagram.
Crestron QM-FTDC
Operations & Installation Guide - DOC. 6312A