Crestron C2N-FT-TPS4/TPS4-U
SCREEN SETTINGS
TIMEOUT SETTINGS
DIAGNOSTICS MENU

Programming Software

Operations & Installation Guide – DOC. 6398
Press the Restore Default Audio Settings button to cancel any changes and restore
all default audio settings: WAV volume = 100%, and WAV function enabled; key
click volume = 100%, and key click function enabled.
Press Return to save the settings and return to the SETUP MENU.
Screen Settings
From the SETUP MENU, press the Screen Settings button to open the SCREEN
SETTINGS screen, shown at left.
Press the Brightness button to open the SCREEN SETTINGS – BRIGHTNESS
screen. Use the UP/DOWN buttons to set the display brightness (0 – 100%). The
area to the right of the buttons shows the relative brightness from 0% to 100%, both
as a numeric value and, for quick visual reference, as an analog bar.
Press the Key Backlight button to open the SCREEN SETTINGS – KEY
BACKLIGHT screen. Use the UP/DOWN buttons to set the key backlight brightness
(0 – 100%). The area to the right of the buttons shows the relative brightness from
0% to 100%, both as a numeric value and, for quick visual reference, as an analog
bar.
Press the LCD Bias button to open the SCREEN SETTINGS – LCD BIAS screen.
Use the UP/DOWN buttons to set the LCD bias (0 – 255). Use the graphic on the
right side of the screen to see the effects of the adjustment. The bias setting is best
when the lines are crisp and dark and the white area around them is bright.
Press Return to save the settings and return to the SETUP MENU.
Timeout Settings
From the SETUP MENU, press the Timeout button to open the SCREEN
SETTINGS – TIMEOUT screen. Use the UP/DOWN buttons to set the timeout
from 0 through 120 minutes, where 0 disables the timeout. Adjustment is in one-
minute increments from 1 to 10; in ten-minute increments from 20-120.
STANDBY timeout turns the display and backlight off when the touchpanel is
inactive for the specified time. When the touchpanel is reactivated, the last screen to
be displayed reappears. The specified time is displayed in minutes. The default
STANDBY timeout is 10 minutes.
Press Return to save the settings and return to the SETUP MENU.
Diagnostics Menu
The Diagnostics button from the MAIN MENU should only be used under
supervision from a Crestron customer service representative during telephone
support. Many options available from the DIAGNOSTICS MENU, shown to the left,
are numeric in nature and their interpretation is beyond the scope of this manual.
Have a question or comment about Crestron software?
Answers to frequently asked questions (FAQs) can be viewed in the Online Help
section of the Crestron website. To post a question or view questions you have
FlipTop Touchpanel Control center: C2N-FT-TPS4/TPS4-U • 17
FlipTop Touchpanel Control Center

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2n-ft-tps4-u

Table of Contents