Crestron C2N-FT-TPS4/TPS4-U
Operations & Installation Guide – DOC. 6398
Typical Connection Diagram when Uploading
NOTE: Use a straight-through serial cable for connection to a 2-Series processor.
1. Open Crestron Toolbox and click Tools | Manage Address Book to display
the communications settings. The DefaultAddressBook.adr file contains
several default address settings. Select Serial on COM 1 for serial
communication.
Crestron Toolbox – "Address Book" Window
The PC communication settings specified in the address book should match
the protocol that the control processor expects. The settings are as follows:
Port = COM 1 through COM 8. Select the correct COM port on the
PC.
Baud rate = Auto Detect.
Parity = None.
Number of data bits = 8.
Number of stop bits = 1.
Hardware handshaking (RTS/CTS) enabled.
Software handshaking (XON/XOFF) not enabled.
FlipTop Touchpanel Control center: C2N-FT-TPS4/TPS4-U • 23
FlipTop Touchpanel Control Center