1.7.3 DC Power Input Connector
This connector connects the included AC adapter DC output cable to supply DC 12.0 V.
1.7.4 Power Switch
This is a power switch of the E30A emulator. Before turning on the power again after shutting off the power, wait about 10
seconds.
1.7.5 USB I/F Connector
This is a USB interface connector for connecting the host machine to this emulator. For details on connecting the emulator and
host machine, refer to "2.5 Connecting the E30A Emulator and the Host Machine".
1.7.6 Maintenance Switch
If this switch is pressed within 2 seconds after turning on the power, the SAFE LED blinks and the emulator switches to
maintenance mode for downloading firmware. In maintenance mode you can download firmware forcibly. For details, refer to
"2.10 Downloading Firmware".
1.7.7 50Ω Coaxial Connector
This included 50Ω coaxial cable (gray) connects this emulator to the user system. For details on connecting the emulator and
user system, refer to "2.6 Connecting the E30A Emulator and the User System".
1.7.8 Option Connector
This connector is provided for connecting to the user system via an option board using the 10-pin flat cable included with the
product. For details on connecting to the user system, refer to "2.6 Connecting the E30A Emulator and the User System".

1.8 Operating Environment

Be sure to use this emulator with the operating environment of the emulator and host machine listed in Table 1.7.
Table 1.7 Operating environmental conditions
Item
Operating temperature
Storage temperature
R20UT0422EJ0501 Rev.5.01
Mar 15, 2016
Description
5 to 35°C (no condensation)
-10 to 60°C (no condensation)