2.9 Checking the Status LEDs Display

Check that the SYS POWER LED and SAFE LED are lighting.
If the SAFE LED is off and the ERROR LED is on, it means that the E30A emulator hardware is not operating normally.
When the SAFE LED is off and the ERROR LED blinks, it means the internal firmware of the E30A emulator is not running
normally. When the status LED indicates abnormal, perform the forced download as follows.

2.10 Downloading Firmware

It is necessary to upgrade the firmware in the cases listed below. Normally, the following are automatically detected when the
emulator debugger is started up, and the firmware is downloaded.
- When you use this product for the first time
- When the firmware has been upgraded
- When the emulator debugger has been upgraded
If downloading firmware is not completed when the power is unexpectedly shut down during a download from the emulator
debugger, the status LEDs show abnormal and the emulator debugger may not start up normally. Download firmware in the
special mode called maintenance mode as explained here following.
(1) Within 2 seconds of activating power to the emulator, press the maintenance switch on it to start maintenance mode. The
System Status SAFE LED begins to blink.
(2) Start up the emulator debugger in maintenance mode. When settings in the Init dialog box are complete, the dialog which
urges to download the firmware will appear. Download firmware following messages. Required time for downloading the
firmware is about 15 seconds.