User's Manual
REJ10J1817-0200
R0E001000EXT00
Rev.2.00
Apr 16, 2010
External Trigger Cable for the E100 Emulator
1. Outline
The external trigger cable R0E001000EXT00 allows tracing of
external signals and output of events through the external trigger
connector of the E100 emulator (R0E001000EMU00).
2. Package Components
(See Figure 1)
R0E001000EXTE0 board
R0E001000FLX10
(E100 emulator side)
Check to see if the R0E001000EXT00 package has all the
flexible cable
following contents before using this product.
(1) R0E001000EXTE0 board............................................ 1 pc.
(2) R0E001000EXTT0 board (with a cable)..................... 1 pc.
(3) R0E001000FLX10 flexible cable................................ 1 pc.
(4) R0E001000EXT00 User's Manual (this document)
R0E001000EXTT0 board with a cable
3. Usage
(See Figure 2)
(user system side)
The usage of the external trigger cable R0E001000EXT00 is
Figure 1 Package Components of the R0E001000EXT
shown in Figure 2.
After checking that the power supplies for the E100 emulator and the user system are turned off, connect the external trigger cable
R0E001000EXT00 according to the following procedure.
(1) Connect R0E001000FLX10 to the R0E001000EXTE0 board.
(2) Open the lid (EXT) of the E100 emulator and connect the R0E001000EXTE0 board to the external trigger connector.
(3) Connect signals to the user-system connection sockets of R0E001000EXTT0.
(4) Connect R0E001000FLX10 to R0E001000EXTT0.
REJ10J1817-0200 Rev.2.00
Page 1 of 4
Apr 16 2010