Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

UNIT SIZE
NOMINAL
IFM
580F
V-PH-Hz
TYPE
STD
208/230-3-60
HIGH
STD
103
460-3-60
(8
1
/
Ton)
2
HIGH
STD
575-3-60
HIGH
STD
208/230-3-60
ALT
HIGH
STD
120
460-3-60
ALT
(10 Ton)
HIGH
STD
575-3-60
ALT
HIGH
STD
208/230-3-60
ALT
HIGH
STD
121
460-3-60
ALT
(10 Ton)
HIGH
STD
575-3-60
ALT
HIGH
LEGEND
FLA
— Full Load Amps
HACR — Heating, Air Conditioning and Refrigeration
IFM
— Indoor (Evaporator) Fan Motor
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
NEC
— National Electrical Code
OFM
— Outdoor (Condenser) Fan Motor
RLA
— Rated Load Amps
*Used to determine minimum disconnect per NEC.
†Fuse or HACR circuit breaker.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load equipment (refer
to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or
HACR breaker. Canadian units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use
the following formula to determine the percent of voltage imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
=
= 457
Determine maximum deviation from average voltage.
(AB) 457 – 452 = 5 v
(BC) 464 – 457 = 7 v
(AC) 457 – 455 = 2 v
Maximum deviation is 7 v.
ELECTRICAL DATA (cont)
VOLTAGE
COMPRESSOR (each)
CONV
RANGE
OUTLET
Min
Max
Qty
NO
YES
187
254
2
NO
YES
NO
YES
414
508
2
NO
YES
NO
YES
518
632
2
NO
YES
NO
YES
NO
187
254
2
YES
NO
YES
NO
YES
NO
414
508
2
YES
NO
YES
NO
YES
NO
518
632
2
YES
NO
YES
NO
YES
NO
187
254
2
YES
NO
YES
NO
YES
NO
414
508
2
YES
NO
YES
NO
YES
NO
518
632
2
YES
NO
YES
452 + 464 + 455
3
1371
3
OFM (each)
IFM
FLA
RLA
LRA
Qty
FLA
5.8
17.3
120.0
2
1.4
10.6
2.6
7.9
70.0
2
0.7
4.8
2.0
5.5
50.0
2
0.6
2.8
5.8
15.8
130
2
1.4
7.5
15.0
2.6
7.9
64
2
0.7
3.4
7.4
2.0
6.6
52
2
0.6
2.0
2.8
5.8
15.8
130
2
1.4
7.5
15.0
2.6
7.9
64
2
0.7
3.4
7.4
2.0
6.6
52
2
0.6
2.8
3.3
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local
electric utility company immediately.
3. For units with power exhaust: If a single power source is to be used, size wire to include
power exhaust MCA and MOCP. Check MCA and MOCP when power exhaust is powered
through the unit (must be in accordance with NEC and/or local codes). Determine the new
MCA including the power exhaust using the following formula:
MCA New = MCA unit only + MCA of Power Exhaust
For example, using a 580F060 unit with MCA = 28.9 and MOCP = 35, with
CRPWREXH030A01 power exhaust.
MCA New = 28.9 amps + 1.6 amps = 30.5 amps
If the new MCA does not exceed the published MOCP, then MOCP would not change. The
MOCP in this example is 35 amps, the MCA New is below 35, therefore the MOCP is
acceptable. If "MCA New" is larger than the published MOCP, raise the MOCP to the next
larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC.
POWER EXHAUST ELECTRICAL DATA
POWER EXHAUST
PART NO.
CRPWREXH030A01
CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH028A01
CRPWREXH029A01
*Single or three phase.
81
COMBUSTION
POWER SUPPLY
FAN MOTOR
FLA
MCA
MOCP†
44.3
50
49.1
60
0.6
49.1
60
53.9
60
21.0
25
23.2
30
0.3
23.2
30
25.4
30
16.7
20
18.4
25
0.3
18.5
25
20.2
25
44.2
50
50.2
60
45.9
50
0.6
51.9
60
53.4
60
59.4
70
21.8
25
27.8
30
22.6
25
0.3
25.3
30
26.6
30
29.3
35
18.1
25
24.1
25
18.7
25
0.3
24.7
25
21.9
30
24.6
30
44.6
50
49.4
60
46.3
60
0.6
51.1
60
53.8
60
58.6
70
22.0
25
24.2
30
22.8
25
0.3
25.0
30
26.8
30
29.0
35
18.1
20
19.8
25
18.7
20
0.3
20.4
25
21.9
25
23.6
25
7
457
APPLICATION
MCA
MCA
MCA
USAGE
(230 V)
(460 V)
(575 V)
036-073*
1.6
N/A
0.64
036-073
N/A
0.68
N/A
090-151*
3.4
N/A
1.32
090-151
N/A
1.4
N/A
ALL*
1.7
N/A
0.68
ALL
N/A
0.7
N/A
MINIMUM UNIT
DISCONNECT SIZE*
FLA
LRA
46
272
52
277
52
316
57
320
22
149
24
151
24
171
27
173
17
109
19
111
19
126
21
128
46
307
52
311
48
326
54
330
57
374
62
378
23
152
25
154
24
191
26
193
28
185
31
187
19
123
21
109
20
155
22
141
23
150
25
136
46
307
52
312
48
326
54
331
57
374
62
379
23
152
25
154
24
191
26
193
28
185
30
187
19
123
21
125
20
150
22
156
23
155
25
151
MOCP
(separate
power source
only)
15
15
15
15
15
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

581a581b581c580f