Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

UNIT 580F
0
036†
1045
036**
1455
048†
1175
048**
1455
060†
1300
060**
1685
072,073††
1460
072,073**
1685
*Approximate fan rpm shown.
†Indicates alternate motor and drive package.
UNIT 580F
0
090,091†
840
090,091**
935
090,091††
1080
103†
935
103††
1080
120,121†
935
120,121***
1085
120,121††
1130
150,151†
1080
150,151***
1130
*Approximate fan rpm shown.
†Indicates standard motor and drive package.
**Indicates alternate drive package only.
ALTITUDE COMPENSATION* — 580F036-073
STANDARD UNITS
74,000 AND 115,000 BTUH
NOMINAL INPUT
ELEVATION
(ft)
Natural Gas
Liquid Propane
Orifice Size†
Orifice Size†
0-2,000
33
2,000
36
3,000
36
4,000
37
5,000
38
6,000
40
7,000
41
8,000
42
9,000
43
10,000
44
11,000
45
12,000
46
13,000
47
14,000
48
*As the height above sea level increases, there is less oxygen per cubic foot of air.
Therefore, heat input rate should be reduced at higher altitudes.
†Orifices available through your local Bryant distributor.
ALTITUDE COMPENSATION* — 580F036-073
LOW NOx UNITS
60,000 AND 90,000 BTUH
ELEVATION
NOMINAL INPUT
(ft)
Natural Gas Orifice Size†
0-2,000
38
2,000
40
3,000
41
4,000
42
5,000
43
6,000
43
7,000
44
8,000
45
9,000
46
10,000
47
11,000
48
12,000
49
13,000
50
14,000
51
*As the height above sea level increases, there is less oxygen per cubic foot of air.
Therefore, the input rate should be reduced at higher altitudes.
†Orifices are available through your local Bryant distributor.
PERFORMANCE DATA (cont)
FAN RPM AT MOTOR PULLEY SETTINGS* — 580F036-073
1
/
1
1
1
/
2
2
2
1009
973
937
901
1423
1392
1360
1328
1135
1094
1054
1013
1423
1392
1360
1328
1266
1233
1200
1166
1647
1608
1570
1531
1421
1382
1343
1304
1647
1608
1570
1531
FAN RPM AT MOTOR PULLEY SETTINGS* — 580F090-151
1
/
1
1
1
/
2
2
815
790
765
910
885
860
1025
1007
988
910
885
860
1025
1007
988
910
885
860
1060
1035
1010
1112
1087
1062
1060
1035
1015
1112
1087
1062
150,000 BTUH
NOMINAL INPUT
Natural Gas
Liquid Propane
Orifice Size†
Orifice Size†
43
30
37
44
31
39
45
31
40
45
32
41
46
32
42
47
34
43
48
35
43
49
36
44
50
37
45
50
39
46
51
41
47
52
42
48
52
43
49
53
44
50
120,000 BTUH
NOMINAL INPUT
Natural Gas Orifice Size
32
33
35
36
37
38
39
41
42
43
44
44
46
47
MOTOR PULLEY TURNS OPEN
2
1
/
3
3
1
/
2
2
865
829
793
1297
1265
1233
973
932
892
1297
1265
1233
1133
1100
1066
1493
1454
1416
1265
1226
1187
1493
1454
1416
**Indicates high-static motor and drive package.
††Indicates standard motor and drive package.
MOTOR PULLEY TURNS OPEN
2
2
1
/
3
2
740
715
690
835
810
785
970
952
933
835
810
785
970
952
933
835
810
785
985
960
935
1037
1012
987
990
970
950
1037
1012
987
††Indicates high-static motor and drive package.
***Indicates alternate motor and drive package.
ALTITUDE COMPENSATION* — 580F090-151
125,000,180,000, AND 224,000
BTUH NOMINAL INPUT
ELEVATION
(ft)
Natural Gas
Orifice Size†
0-2,000
31
2,000
32
3,000
32
4,000
32
5,000
33
6,000
34
7,000
35
8,000
36
9,000
37
10,000
38
11,000
39
12,000
40
13,000
41
14,000
42
*As the height above sea level increases, there is less oxygen per cubic foot of air.
Therefore, heat input rate should be reduced at higher altitudes.
†Orifices available through your local Bryant distributor.
ALTITUDE DERATING FACTOR*
ELEVATION
(ft)
0-2,000
2,001-3,000
3,001-4,000
4,001-5,000
5,001-6,000
*Derating of the unit is not required unless the heating value of the gas exceeds the val-
ues listed in the table above, or if the elevation exceeds 6000 ft. Derating conditions
must be 4% per thousand ft above 2000 ft. For example, at 4000 ft, if the heating value
of the gas exceeds 1000 Btu/ft
above 6000 ft, the same formula applies. For example, at 7000 ft, the unit will require a
28% derating of the maximum heating value per the National Fuel Gas Code.
IMPORTANT: Local utility companies may be reducing heat content of gas at altitudes
above 2000 ft. If this is being done, changing spuds may not be required.
75
4
4
1
/
5
2
757
721
685
1202
1170
1138
851
811
770
1202
1170
1138
1033
1000
966
1377
1339
1300
1148
1109
1070
1377
1399
1300
3
1
/
4
4
1
/
5
2
2
665
635
615
590
760
735
710
685
915
897
878
860
760
735
710
685
915
897
878
860
760
735
710
685
910
885
860
835
962
937
912
887
925
905
880
860
962
937
912
887
250,000 BTUH
NOMINAL INPUT
Liquid Propane
Natural Gas
Orifice Size†
Orifice Size†
41
30
42
30
42
31
42
32
43
33
43
34
44
35
44
36
45
37
46
38
47
39
47
40
48
41
48
42
MAXIMUM HEATING VALUE
(Btu/ft
1,100
1,050
1,000
950
900
3
, the unit will require a 16% derating. For elevations
5
1
/
6
2
1107
1075
1107
1075
933
900
5
1
/
6
2
862
830
862
830
Liquid Propane
Orifice Size†
38
39
40
41
42
43
43
44
44
45
45
46
47
47
3
)