Bryant 579F User Manual page 74

Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

1. Values include losses for filters, unit casing, and wet coils. See this
page for accessory/FIOP static pressure information.
2. Extensive motor and electrical testing on these units ensures that
the full range of the motor can be utilized with confidence. Using fan
motors up to the wattage ratings shown will not result in nuisance
tripping or premature motor failure. Unit warranty will not be
SOUND
UNIT 580F
RATING
60 Hz (dB)
036-072
81
073
80
090
87
091, 103
82
120
88
121
84
150
87
151
86
NOTE: Indoor sound power is available in Bryant's Electronic Catalog program (ECAT) for specific operating parameters.
ACCESSORY/FIOP ECONOMIZER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) — 580F036-073
COMPONENT
Vertical EconoMi$er IV and EconoMi$er2
Horizontal EconoMi$er IV and EconoMi$er2
LEGEND
FIOP — Factory-Installed Option
ACCESSORY/FIOP ECONOMISER IV AND ECONOMI$ER2 STATIC PRESSURE* (in. wg) — 580F090-151
COMPONENT
Vertical EconoMi$er IV
and EconoMi$er2
Horizontal EconoMi$er IV
and EconoMi$er2
LEGEND
FIOP — Factory-Installed Option
PERFORMANCE DATA (cont)
GENERAL NOTES FOR FAN PERFORMANCE DATA TABLES
OUTDOOR SOUND POWER (Total Unit)
A-WEIGHTED
(dB)
80.5
80.0
86.4
82.0
87.6
84.0
86.4
86.0
1250
1500
0.045
0.065
2250
2500
2750
3000
0.06
0.075
0.09
0.115
0.1
0.125
0.15
affected. See Evaporator-Fan Motor Performance table on page 79
for additional information.
3. Use of a field-supplied motor may affect wire sizing. Contact your
Bryant representative for details.
4. Interpolation is permissible. Do not extrapolate. (Belt drive units
only.)
63
125
250
56.8
75.8
72.4
59.1
68.9
68.7
83.2
87.4
83.5
62.2
69.3
71.5
97.6
90.4
85.7
64.6
71.7
73.3
83.7
87.2
83.4
63.7
69.9
72.5
CFM
1750
2000
0.08
0.12
0.1
0.125
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should be used in conjunction
with the Fan Performance tables to determine indoor blower rpm and
watts.
CFM
3250
3500
3750
4000
0.13
0.15
0.17
0.195
0.18
0.21
0.25
0.275
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in con-
junction with the Fan Performance tables to determine blower rpm and
watts.
74
OCTAVE BANDS
500
1000
2000
72.9
74.8
75.4
71.9
74.0
68.9
82.8
83.0
77.7
74.7
76.2
72.9
84.8
83.9
77.5
76.9
77.6
73.7
82.8
83.0
77.7
78.2
81.1
77.3
2250
2500
2750
0.145
0.175
0.22
0.15
0.18
0.225
4250
4500
4750
5000
0.22
0.25
0.285
0.325
0.3
0.34
0.388
4000
8000
71.3
69.1
65.7
59.0
71.8
67.0
68.7
61.5
71.3
65.8
70.6
63.7
71.8
67.0
73.3
66.8
3000
0.255
0.275
5250
6250
0.36

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

581a581b581c580f