Bryant 579F User Manual page 18

Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

UNIT
NOMINAL
581A
TONS
155230
13
180275
15
UNIT
NOMINAL
581A
TONS
155300
13
180360
15
LEGEND
dB
— Sound Levels (decibels)
db
— Dry Bulb
EER — Energy Efficiency Ratio
IPLV — Integrated Part-Load Values
wb
— Wet Bulb
*Air Conditioning and Refrigeration Institute.
NOTES:
1. Rated in accordance with ARI Standards 360 and 270.
2. ARI ratings are net values, reflecting the effects of circulating fan
heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air tempera-
ture and 95 F db air entering outdoor unit.
HEATING
UNIT 581A
INPUT (Btuh)
Stage 2/Stage 1*
155230
230,000/172,000
155300
300,000/225,000
180275
275,000/206,000
180360
360,000/270,000
*All units are 2-stage heat.
†Minimum heating cfm must be maintained to ensure proper heating operation.
NOTE: Minimum allowable temperature of mixed air entering the heat exchanger during first stage
heating is 45 F. There is no minimum mixed-air limitation during second-stage heating. For entering
air temperatures below 45 F, both stages of heat must be energized together to minimize conden-
sation issues and ensure proper unit operation. Mixed air below 35 F optional stainless steel heat
exchangers are recommended.
LOW OUTDOOR AIR TEMPERATURE
COOLING OPERATION LIMITS
TEMPERATURE LIMIT (F)
UNIT SIZE
Standard
581A
Unit
Low Ambient Kit
155, 180
40
ARI* CAPACITY RATINGS — 581A155,180
LOW HEAT UNITS
NET COOLING
CAPACITY
(Btuh)
134,000
180,000
HIGH HEAT UNITS
NET COOLING
CAPACITY
(Btuh)
134,000
180,000
HEATING CAPACITIES AND EFFICIENCIES — 581A155-180
OUTPUT
CAPACITY
(Btuh)
186,000
243,000
223,000
292,000
Unit With
Unit With
Motormaster®
Control
20
–20
TOTAL
EER
WATTS
12,209
10.60
17,064
10.50
TOTAL
EER
WATTS
12,218
10.60
17,179
10.50
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature
and 80 F db outdoor entering-air temperature.
4.
All 581A155, 180 units are in compliance with ASHRAE 90.1-
1999 Energy Standard for minimum EER requirements. Refer to
state and local codes or visit the following website: http://bcap-
energy.org to determine if compliance with this standard pertains
to a given geographical area of the United States.
AGA STEADY
TEMPERATURE
RISE (F)
EFFICIENCY (%)
15-45
30-60
15-45
20-50
AIR QUANTITY LIMITS (Cooling)
UNIT 581A
155
180
18
SOUND
RATING
IPLV
(dB)
88
88
SOUND
RATING
IPLV
(dB)
88
88
MINIMUM HEATING
STATE
CFM†
81.0
3750
81.0
3830
81.0
4580
81.0
5400
MINIMUM CFM
MAXIMUM CFM
3900
6500
4500
7500
11.4
11.4
11.4
11.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

581a581b581c580f

Table of Contents