Bryant 579F User Manual page 239

Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

581A155 (12 Tons)
Temp (F)
Air Ent
Cond
54
58
62
TC
152
156
161
60
SHC
152
144
135
kW
7.56
7.65
7.74
TC
148
152
156
SHC
148
141
133
70
kW
8.5
8.58
8.67
TC
146
150
154
75
SHC
146
139
132
kW
9.02
9.1
9.18
TC
142
145
149
85
SHC
142
136
129
kW
10.1
10.2
10.3
TC
138
141
143
95
SHC
138
133
127
kW
11.4
11.4
11.5
TC
134
136
138
SHC
134
129
124
105
kW
12.7
12.8
12.8
TC
129
130
132
SHC
129
125
121
115
kW
14.2
14.2
14.3
TC
124
125
126
125
SHC
124
121
118
kW
15.8
15.8
15.9
581A155 (12 Tons) (cont)
Temp (F)
Air Ent
Cond
54
58
TC
175
175
60
SHC
175
173
kW
8.03
8.05
TC
170
171
70
SHC
170
169
kW
8.98
8.99
TC
168
168
75
SHC
168
167
kW
9.5
9.51
TC
163
163
85
SHC
163
162
kW
10.6
10.6
TC
158
158
SHC
158
157
95
kW
11.9
11.9
TC
152
152
SHC
152
152
105
kW
13.2
13.2
TC
146
146
115
SHC
146
146
kW
14.7
14.7
TC
140
140
125
SHC
140
140
kW
16.4
16.4
LEGEND
BF
— Bypass Factor
Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW
— Compressor Motor Power Input
ldb
— Leaving Dry-Bulb
lwb — Leaving Wet-Bulb
SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC
— Total Capacity (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t ldb = t edb –
1.10 x cfm
t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving evapo-
rator coil (h lwb )
total capacity (Btuh)
h lwb = h ewb –
4.5 x cfm
Where: h ewb = Enthalpy of air entering evaporator coil
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
PERFORMANCE DATA
COOLING CAPACITIES — STANDARD UNITS
3600/0.01
67
72
76
80
54
174
189
201
213
161
114
92.9
75.4
57.5
161
8.01
8.33
8.6
8.86
7.76
169
183
195
206
157
112
90.6
73.2
55.4
157
8.97
9.26
9.53
9.8
8.7
166
181
192
204
155
111
89.7
72.2
54.6
155
9.45
9.8
10.1
10.4
9.22
161
175
186
196
151
109
87.4
70
52.4
151
10.6
10.9
11.2
11.5
10.3
155
168
179
189
147
106
85
67.7
50.1
147
11.8
12.2
12.4
12.7
11.6
149
162
172
181
141
104
82.4
65.3
47.7
141
13.2
13.5
13.8
14.1
12.9
143
155
164
172
136
101
79.8
62.7
45.1
136
14.6
15
15.3
15.6
14.4
136
147
156
163
131
98.2
77
60.1
42.5
131
16.2
16.6
17
17.2
16.1
5625/0.02
62
67
72
176
187
202
171
142
110
8.07
8.3
8.61
171
181
195
168
140
108
9.01
9.23
9.55
169
179
192
166
139
107
9.52
9.75
10.1
164
172
185
162
136
104
10.6
10.9
11.2
158
166
178
157
134
102
11.9
12.1
12.4
152
159
171
152
131
99.3
13.2
13.4
13.8
146
151
163
146
128
96.6
14.7
14.9
15.3
140
144
155
140
125
93.7
16.4
16.5
16.9
Evap Air — Cfm/BF
4375/0.01
Evap Air — Ewb (F)
58
62
67
72
76
164
167
180
195
207
156
150
125
99.6
78.7
7.82
7.88
8.14
8.46
8.72
160
162
174
189
200
153
148
123
97.3
76.5
8.75
8.81
9.07
9.39
9.66
158
160
172
186
197
151
146
122
96.2
75.5
9.27
9.31
9.58
9.91
10.2
153
154
166
179
190
147
144
119
93.9
73.2
10.4
10.4
10.7
11
11.3
148
149
160
173
183
144
141
117
91.6
70.9
11.6
11.6
11.9
12.3
12.6
142
143
153
166
176
139
137
114
89
68.4
13
13
13.3
13.6
13.9
137
138
146
158
168
135
133
111
86.3
65.9
14.4
14.5
14.7
15.1
15.5
131
132
140
150
159
130
128
109
83.5
63.2
16.1
16.1
16.4
16.7
17.1
Evap Air — Cfm/BF
Evap Air — Ewb (F)
76
80
54
58
214
224
180
180
83.8
57.3
180
180
8.87
9.1
8.14
8.15
207
216
175
176
81.5
55.2
175
176
9.81
10
9.09
9.1
203
213
173
173
80.5
54.4
173
173
10.3
10.6
9.62
9.62
196
205
168
168
78.2
52.2
168
168
11.5
11.7
10.7
10.7
189
196
162
162
75.9
49.8
162
162
12.7
12.9
12
12
181
187
157
157
73.3
47.4
157
157
14.1
14.3
13.4
13.4
172
177
150
150
70.7
44.9
150
150
15.6
15.8
14.9
14.9
163
167
144
144
67.9
42.4
144
144
17.2
17.4
16.5
16.5
BYPASS
FACTOR
(BF)
.05
.10
.20
.30
Interpolation is permissible.
Correction Factor = 1.10 x (1 – BF) x (edb – 80).
4. Use chart below for bypass factor.
CFM
54
3600
0.355
4375
0.439
5000
0.486
5625
0.525
6250
0.551
239
5000/0.01
80
54
58
62
67
218
169
171
172
184
57.5
169
166
162
134
8.97
7.92
7.95
7.98
8.24
211
165
166
167
179
55.3
165
162
160
132
9.91
8.86
8.89
8.91
9.16
208
163
164
164
176
54.6
163
161
158
131
10.5
9.39
9.41
9.43
9.68
200
158
159
159
170
52.3
158
157
155
128
11.6
10.5
10.5
10.5
10.8
192
153
153
154
164
50
153
153
152
126
12.8
11.8
11.8
11.8
12
184
148
148
148
157
47.5
148
148
148
123
14.2
13.1
13.1
13.1
13.4
175
142
142
142
149
45
142
142
142
120
15.7
14.6
14.6
14.6
14.8
165
136
136
136
142
42.5
136
136
136
117
17.3
16.3
16.2
16.2
16.4
6250/0.02
62
67
72
180
190
204
180
151
115
8.16
8.36
8.66
176
184
198
176
148
113
9.11
9.3
9.61
173
181
195
173
147
112
9.62
9.81
10.1
168
175
188
168
145
109
10.8
10.9
11.2
162
168
180
162
142
107
12
12.1
12.5
157
161
173
157
139
104
13.4
13.5
13.9
150
153
165
150
136
102
14.9
14.9
15.4
144
146
156
144
133
98.7
16.5
16.6
17
ENTERING AIR DRY-BULB TEMP (F)
79
78
77
76
75
81
82
83
84
85
Correction Factor
1.04
2.07
3.11
4.14
5.18
.98
1.96
2.94
3.92
4.90
.87
1.74
2.62
3.49
4.36
.76
1.53
2.29
3.05
3.82
ENTERING WET-BULB (F)
58
62
67
72
Bypass Factor
0.158
0.054
0.038
0.049
0.255
0.112
0.043
0.057
0.314
0.126
0.054
0.037
0.360
0.174
0.066
0.073
0.410
0.202
0.080
0.079
72
76
80
199
211
222
105
81.3
57.4
8.55
8.82
9.06
193
204
214
103
79.1
55.3
9.49
9.76
9.99
189
201
212
101
78.1
54.5
9.99
10.3
10.6
183
194
203
99.1
75.8
52.2
11.1
11.4
11.7
177
187
195
96.9
73.5
49.9
12.4
12.7
12.9
169
179
186
94.3
70.9
47.4
13.7
14
14.3
161
171
177
91.6
68.4
45
15.2
15.6
15.7
153
162
167
88.7
65.7
42.4
16.8
17.2
17.4
76
80
216
226
86.2
57.2
8.93
9.14
209
218
84
55.1
9.87
10.1
206
215
83
54.3
10.4
10.6
198
206
80.6
52.1
11.5
11.8
190
197
78.3
49.7
12.8
13
182
188
75.7
47.4
14.2
14.4
174
178
73.1
44.8
15.7
15.8
164
168
70.2
42.3
17.3
17.4
under 75
over 85
Use formula
shown below.
76
80
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000