Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

581C048 (4 Tons)
Temp (F)
Air Entering Evaporator -- CFM/BF
Air Ent
1200/0.05
Condenser
Air Entering Evaporator -- Ewb (F)
(Edb)
62
67
72
TCG
46.3
51.1
55.7
75
SHG
39.9
33.8
27.1
CMP 2.36
2.37
2.38
TCG
42.9
49
54
85
SHG
38.5
33
26.6
CMP 2.69
2.71
2.72
TCG
38.7
45.8
51.9
95
SHG
36.5
31.8
25.9
CMP 3.05
3.08
3.11
TCG
34.4
41.1
49.1
105
SHG
34.3
30
24.9
CMP 3.42
3.48
3.53
TCG
31.4
36.3
44.7
115
SHG
31.4
28.1
23.5
CMP 3.85
3.9
3.96
TCG
28.2
31.1
39.8
SHG
28.1
26.2
21.8
125
CMP 4.31
4.35
4.42
581C060 (5 Tons)
Temp (F)
Outdoor
1500/0.26
Air Ent
(Edb)
57
62
67
TCG
57
60.2
66.5
75
SHG
55.3
50.5
42.4
CMP
3.1
3.11
3.12
TCG
54.1
56.9
64
85
SHG
52.6
49.1
41.4
CMP
3.5
3.52
3.54
TCG
50.2
53
61.1
95
SHG
48.8
47.4
40.3
CMP
3.94
3.95
3.99
TCG
47.4
47.9
56.5
105
SHG
46
45.2
38.7
CMP
4.42
4.42
4.48
TCG
43.1
43.2
50.3
115
SHG
41.8
42
36.4
CMP
4.92
4.92
4.98
TCG
39
39
43.9
SHG
37.9
37.9
34.1
125
CMP
5.47
5.46
5.52
LEGEND
BF
— Bypass Factor
Edb
— Entering Dry Bulb
Ewb
— Entering Wet Bulb
COMP —
Compressor Power kw
SHG
— Gross Sensible Capacity (1000 Btuh)
TCG
— Compressor Cooling Capicity (1000 Btuh)
PERFORMANCE DATA — 581C
COOLING CAPACITIES — 581C024-060 STANDARD UNITS (cont)
1600/0.07
2000/0.09
62
67
72
62
48.8
53.5
58
50.7
54.9
46.3
38.6
29.8
50.6
42.7
2.37
2.38
2.39
2.37
2.38
46.2
51.5
56.4
49.2
52.8
45.2
37.9
29.4
49.1
42.2
2.71
2.72
2.74
2.72
2.72
42.6
48.8
54.2
46.8
50.4
42.5
37.1
28.9
46.8
41.6
3.07
3.1
3.12
3.1
3.11
39
43.8
51.5
43.3
46.3
39
35.3
28.2
43.3
40.4
3.47
3.5
3.54
3.5
3.52
35.8
38.4
47.3
39.2
40.6
35.8
33.3
26.9
39.2
38.1
3.9
3.92
3.98
3.93
3.94
31.9
33
41.6
35.3
35.4
31.9
31.1
25.1
35.3
35.4
4.36
4.37
4.44
4.4
4.4
Indoor Entering Air -- CFM/BF
1750/.31
Indoor Entering Air -- Ewb (F)
72
57
62
67
72
72
60.3
62.3
68.5
73.8
33.5
58.6
55.2
45.7
35.4
3.14
3.11
3.12
3.13
3.15
70.2
58.3
59.7
65.9
72
33
56.6
54.1
44.8
35
3.56
3.52
3.53
3.54
3.57
67.5
55
55.6
62.9
69.3
32.2
53.4
52.3
43.8
34.2
4.02
3.97
3.97
4.01
4.03
64.3
50.9
51
59.5
66.1
31.1
49.5
49.5
42.6
33.2
4.51
4.44
4.44
4.5
4.53
60.8
47.3
47.3
52.6
62.6
30
45.9
45.9
40.2
32.1
5.05
4.96
4.96
5
5.07
55.7
42.3
42.3
46.9
58.5
28.3
41.1
41
38.2
30.8
5.62
5.51
5.51
5.55
5.64
67
72
59.1
32
2.39
57.4
31.7
2.74
55.5
31.4
3.12
52.8
30.9
3.54
49.5
30.1
4
43.9
28.4
4.46
2000/.35
57
62
67
72
63.2
64.1
69.7
75.6
61.3
59.5
48.6
37.4
3.11
3.12
3.13
3.16
60.9
61.4
67.3
73.4
59.2
58.4
48
36.9
3.53
3.54
3.54
3.58
58.6
58.6
64.3
70.6
56.9
56.8
47.2
36.1
3.99
3.99
4.02
4.03
54.7
54.8
60.9
67.4
53.1
53.2
45.9
35.2
4.47
4.47
4.51
4.54
50.1
50.1
55.6
63.9
48.7
48.7
44.1
34.2
4.98
4.98
5.02
5.08
46.1
46.1
48.2
59.7
44.8
44.8
41.6
32.9
5.54
5.54
5.56
5.66
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
t
= t
ldb
edb
t
= Wet-bulb temperature corresponding to enthalpy of air
lwb
leaving evaporator coil (h
h
= h
lwb
ewb
Where: h
= Enthalpy of air entering evaporator coil.
ewb
3. The SHC is based on 80 F edb temperature of air entering evapo-
rator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 – BF) x (edb – 80).
152
2500/.45
57
62
67
72
67.4
67.4
71.8
77.6
65.5
65.5
54.4
40.7
3.12
3.12
3.14
3.17
65.3
65.2
69.6
75.3
63.4
63.4
54.4
40.4
3.54
3.54
3.56
3.59
62.8
62.8
66.4
72.7
61
61
53.4
40
4.01
4.01
4.02
4.05
59.9
60
62.9
69
58.2
58.3
52.4
38.8
4.5
4.5
4.52
4.54
56
55.9
58.2
65.4
54.4
54.3
50.8
37.9
5.03
5.03
5.05
5.08
50.9
50.9
51.3
61.4
49.4
49.4
48.2
36.9
5.59
5.59
5.59
5.66
sensible capacity (Btuh)
1.10 x cfm
)
lwb
total capacity (Btuh)
4.5 x cfm