Siemens SITRANS F TRANSMAG 2 Operating Instructions Manual page 109

Electromagnetic flometers
Table of Contents

Advertisement

Table B-2
Byte
No.
These components may adopt the following values in SITRANS F:
Table B-3
Formats of the quality bits
Bit
Bit
7
6
0
0
bad
0
1
uncertain
1
0
good (not cascade)
Table B-4
Formats of the substatus bits
Bit
Bit
Bit
5
4
3
0
0
0
0
0
1
0
1
1
0
0
0
0
0
0
0
0
1
0
1
0
0
1
0
0
0
0
TRANSMAG 2 with MAG 911/E
Operating Instructions, 03/2021, A5E00102775-AC
Status byte formats
7 (MSB)
6
5
Quality
Profile Designation
Bit
Profile Designation
2
1
configuration error
1
device failure
sensor failure
1
out of service
0
non specific
1
last usable value
0
substitute set
0
initial value
0
sensor conversion not accurate
O.K.
1
update event
Bit
5
4
Substatus
Measured value cannot be used
Measured value uncertain
Measured value OK
Parameter error, i.e. upper and lower value for meas‐
uring or output scale identical
RAM or EEPROM defective;
Diagnostic bit "Memory error" is also set and the diag‐
nosis message "RAM error" or "EEPROM error" dis‐
played locally
Measurement was not possible;
Diagnostic bit "Memory error" is also set and the diag‐
nosis message "Measuring path fault" displayed locally
Corresponding function block is in "Out of service"
mode (see parameter "MODE_BLK actual")
Measurement contains too many implausible meas‐
ured values, e.g. due to solids or gas bubbles in the
medium.
Diagnostic bit "Memory error" is also set and the diag‐
nosis message "RAM error" or "EEPROM error" dis‐
played locally
Failsafe mode: the current measured value has been
replaced with the last good measured value
Failsafe mode: the current measured value has been
replaced with the agreed failsafe value
Failsafe mode or state before the first measurement:
the current measured value has been replaced with
the start value
Measured value is outside the sensor limits
(Table 5-1, Page 30)
Measured value is OK (normal state)
A parameter with the "static" memory attribute has
been changed locally or on the PROFIBUS
Profibus Communication
B.5 Status bytes
3
2
1
Meaning
Meaning
0 (LSB)
Limits
109

Advertisement

Table of Contents
loading

Table of Contents