Remove the filter, put it in a plastic bag, seal it and
dispose it of according to the current legislation on the type
of material extracted
To reassemble the filter, operate in reverse order:
-
Insert the new filter in the support ring and lock it by means of the
fastening clip (H)
-
lock the filter to the cage by tying the special laces on the bottom
side
-
insert the filter with ring and cage inside the filtering chamber,
paying particular attention to align the cage with the filter shaking
lever
-
insert the lever end into the appropriate seat on the bottom of the
cage and then insert the fastening clip
-
place the HEPA filter and/or the S.P. cleaning system (if provided) on
top of the filter
-
position the vacuum cleaner's cap, insert the hose on the cap and
tighten the fastening clip. Then lock the cap with the appropriate
locking hooks
-
lock the bin under the filter chamber
-
connect the vacuum cleaner to the mains
-
turn
on
the
operation.
5.4
Replacing the HEPA filter (if provided)
Proceed as follows to replace the filter:
vacuum
cleaner,