Preparing The Rack Enclosure - IBM xSeries 240 81Y Hardware Maintenance Manual

Table of Contents

Advertisement

Before you begin
Before you begin to install the server in the rack,
review the safety and handling guidelines
specified under "Safety information" on
page 224.
To ensure rack stability, plan the installation of
servers in the rack starting from the bottom. If
you are installing different server models in the
rack enclosure, install the heaviest models in the
lower part of the rack enclosure. For more
information, refer to the IBM Rack Configurator
program provided with the ServerGuide CDs.
Refer to ServerGuide information provided with
the server section of this Server Library.
Review the documentation that comes with the
rack enclosure for safety or cabling
considerations. Ensure that the planned
installation is within the rack's guidelines for heat
generation, electrical requirements, air flow, and
mechanical loading.
Verify that the rack can meet the operating
parameters, as detailed in "Specifications" on
page 52.
Turn off the server, if it is on.

Preparing the rack enclosure:

mounting hardware to the rack enclosure:
1. Mark the positions of the slide brackets and the cable
management arm on the mounting rails of the rack
enclosure.
a. Position the template on the front mounting rail,
aligning the holes.
b. Mark the holes for the slide bracket cage nuts,
using the dots supplied with the template. Also
mark the holes for the chassis bracket cage
nuts.
c. Move the template to the rear mounting rails.
Mark the locations for the slide bracket cage
nuts and the cable-management-arm mounting
bracket.
Note
You must align the slide brackets correctly or the
installation cannot be completed.
2. Install the cage nuts or clip nuts, as required for the
rack enclosure, in the marked positions.
150
xSeries 240 HMM