Error Code/Symptom
180-XXX-003
(Failed System Board LED
test)
180-XXX-004
(Failed Processor Board
LED test)
180-XXX-005
(Failed SCSI Backplane
LED test)
201-XXX-001
(Failed Memory test)
201-XXX-002
(Failed Memory test)
201-XXX-003
(Failed Memory test)
201-XXX-004
(Failed Memory test)
201-XXX-999
(Multiple DIMM failure, see
error text.)
202-XXX-001
(Failed System Cache test)
202-XXX-002
(Failed System Cache test
on Optional Microprocessor)
206-XXX-000
(Failed Diskette Drive test)
215-XXX-000
(Failed IDE CD-ROM test)
217-XXX-000
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
217-XXX-001
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
200
xSeries 240 HMM
FRU/Action
1. System Board
1. Processor Board
2. System Board
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
1. DIMM Location J4
1. DIMM Location J3
1. DIMM Location J2
1. DIMM Location J1
1. See error text for
failing DIMMs
1. Microprocessor
1. Optional
Microprocessor
1. Diskette Drive cable
2. Diskette Drive
1. CD-ROM Drive
Cables
2. CD-ROM Drive
3. System Board
1. Fixed Disk 1
1. Fixed Disk 2