Victoria Arduino Adonis+ 2 Gr Technical Manual page 88

Table of Contents

Advertisement

Available languages

Available languages

9.
DISPLAY AND KEY
INDICATIONS
DIAGNOSIS OF ERROR
DELIVERY ERROR
DOSER ERROR
LEVEL ERROR
86
MACHINE FUNCTION MESSAGES
CAUSE
At the time of the diagnosis the
system presents faults within the
control unit EPROM.
On reaching delivery time limit
(120 seconds) the doser doesn't
send out its set commands.
If the doser doesn't send out its
set commands within the rst
three seconds from delivery
onset.
If after 90 sec of machine func-
tioning the water level is not re-
established.
EFFECT
If after 90 sec of machine func-
tioning the water level is not re-
established.
The display indicator and the
Press the RESET key or one of
'continuous' key belonging to the
relative unit will ash on and off.
If the delivery isn't manually halt-
Press the RESET key or one of
ed, the maximum time limit (120
sec) will be blocked.
The display indicator will ash
Turn the machine off and then
on and off. The pump is de-ac-
turn it on again. All its functions
tivated. The resistor and all the
functions are halted.
SOLUTION
.
the keys
.
the keys
will be re-activated.
NOTES