Press ENTER, and the display will read:
PROGRAM. DOSES
SELECT
All the programmable keys will start to flash on and
off.
Press the coffee key you wish to program; the dis-
play will read:
VOLUME C.C:
Followed by the dose amount already set by the
manufacturers.
Vary the dose, by pressing the buttons
By pressing the coffee key you want to program,
delivery will be started up (in the meantime all the
other keys will turn off).
Once you have the required dose, press the con-
tinuous coffee key
to stop pouring.
The display will show the new dose amount which
can still be changed by means of the keys
Press the ENTER key to confirm the programmed
dose.
Press the RESET key to cancel programming.
The programmed coffee key will switch off.
Hot Water
Press the
button and make sure that it lights
up. The display will read:
PROGRAM. DOSES
SECONDS X.X
The value X.X is the default setting.
.
Press the
keys to vary the hot water delivery
time.
If a new sampling is desired press the
again. Delivery starts. When the desired dose has
been reached press the button again
The display will show the new dose value set which
.
can still be changed by pressing the
Press the ENTER key or go on to a further selection to
terminate the operation..
Press the RESET key to cancel programming.
The
button will turn off.
Timed steam
Press the
button and make sure it lights up.
In those models provided with a temperature probe
(optional) the control unit automatically recognizes
the presence of the probe and the display will read:
PROGRAM. DOSES
STEA.TEM.
followed by the temperature set previously by the
manufacturer.
button
Press the
keys to vary the temperature of the
beverage you want to heat. When the desired tem-
.
perature has been reached, the steam delivery will
keys.
°C
71