5.3 Loop back test
Start Loop back test which the message is send back to the own ship. The transmitting and
receiving message should be printed out.
1) Make a test message by "New" ([F1]-1).
2) Set following items by "Transmit Message" ([F3]-1).
- Priority
- Destination Type
- Country/Ocean Code : The Ocean region to be selected
- Station ID
- LES ID
- Option
Confirmation
Send Delay
Delivery Dela
Code
3) Move the cursor onto "Transmit" and press [Enter].
Select "YES" and press [Enter] to start the transmission.
4)
5) When the same message is received after 5 to10 minutes, the test result is OK. If the
message cannot received correctly, confirm "Delivery" in "Send Message Log"
([F6]-1). See page 7.
5.4 EGC receiving
The alarm is checked by following the message priority.
The alarm is sounded from IC-305 and the Terminal unit by DIS/URG Message.
See page 2-17. The EGC receiving message should be printed out. See page 4-6.
: Normal
: TELEX
POR: 582, IOR: 583, AOR-W: 584, AOR-E: 581
: To enter the own IMN
: LES
: ON
: 00:00
: Immediate
: IA5